ez80190 ZiLOG Semiconductor, ez80190 Datasheet - Page 49

no-image

ez80190

Manufacturer Part Number
ez80190
Description
Ez80190 Microprocessor
Manufacturer
ZiLOG Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ez80190AZ050EC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
ez80190AZ050EC00TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
ez80190AZ050EG
Manufacturer:
TYCO
Quantity:
120
Part Number:
ez80190AZ050EG
Manufacturer:
Zilog
Quantity:
70
Part Number:
ez80190AZ050EG
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
ez80190AZ050SC
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
ez80190AZ050SC00TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
ez80190AZ050SG
Manufacturer:
ZiLOG
Quantity:
135
PS006613-0306
Bit
Reset
CPU Access
Note: R = Read Only; R/W = Read/Write.
Bit
Position
7
PRT_IRQ
6
IRQ_EN
5
4
PRT_MODE
[3:2]
CLK_DIV
The Timer Control register can be read or written to. The timer reload registers are
Write Only and are located at the same I/O address as the timer data registers,
which are Read Only.
Timer Control Registers
The Timer Control registers, detailed in
the timer, including enabling the timer, selecting the clock divider, enabling the
interrupt, selecting between CONTINUOUS and SINGLE PASS modes, and
enabling the automatic reload feature.
(TMR0_CTL = 0080h, TMR1_CTL = 0083h, TMR2_CTL = 0086h,
TMR3_CTL = 0089h, TMR4_CTL = 008Ch, TMR5_CTL = 008Fh)
Value
0
1
0
1
0
0
1
00
01
10
11
Description
The timer has not reached its end-of-count value. This bit is
reset to 0 every time the TMRx_CTL register is read.
The timer has reached its end-of-count value. If IRQ_EN is set
to 1, an interrupt signal is sent to the CPU. This bit remains 1
until the TMRx_CTL register is read.
Timer interrupt requests are disabled.
Timer interrupt requests are enabled.
Reserved
The timer operates in SINGLE PASS mode. PRT_EN (bit 0) is
reset to 0, and counting stops when the end-of-count value is
reached.
The timer operates in CONTINUOUS mode. The timer reload
value is written to the counter when the end-of-count value is
reached.
Clock ÷ 2 is the timer input source.
Clock ÷ 4 is the timer input source.
Clock ÷ 8 is the timer input source.
Clock ÷ 16 is the timer input source.
R
7
0
Table 5. Timer Control Register
R/W
6
0
PRELIMINARY
R/W
5
0
R/W
Table
4
0
5, are used to control operation of
R/W
3
0
eZ80190 Product Specification
R/W
2
0
Programmable Reload Timers
R/W
1
0
R/W
0
0