tmp89fm42 TOSHIBA Semiconductor CORPORATION, tmp89fm42 Datasheet - Page 309

no-image

tmp89fm42

Manufacturer Part Number
tmp89fm42
Description
8 Bit Microcontroller
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
tmp89fm42AUG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42LUG
Manufacturer:
ST
Quantity:
500
Part Number:
tmp89fm42LUG
Manufacturer:
TOSHIBA
Quantity:
745
Part Number:
tmp89fm42LUG
Manufacturer:
TOSHIBA
Quantity:
1 000
Part Number:
tmp89fm42LUG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG
Manufacturer:
PROCONN
Quantity:
3 705
Part Number:
tmp89fm42UG
Manufacturer:
TOSHIBA/PBF
Quantity:
29
Part Number:
tmp89fm42UG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG
0
Company:
Part Number:
tmp89fm42UG
Quantity:
15 795
Company:
Part Number:
tmp89fm42UG
Quantity:
2 400
Part Number:
tmp89fm42UG(C
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG(C,JZ)
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG(CZHZ)
0
Part Number:
tmp89fm42UG(JZ)
Manufacturer:
Toshiba
Quantity:
10 000
RA001
AD converter control register 1
ADCCR1
(0x0034)
Note 1: Do not perform the following operations on the ADCCR1 register while AD conversion is being executed
Note 2: If you want to disable all analog input channels, set AINEN to "0".
Note 3: Although analog input pins are also used as input/output ports, it is recommended for the purpose of maintaining the accu-
Note 4: When STOP, IDLE0 or SLOW mode is started, ADRS, AMD and AINEN are initialized to "0". If you use the AD converter
Note 5: After the start of AD conversion, ADRS is automatically cleared to "0" ("0" is read).
(ADCCR2<ADBF>="1").
- Changing SAIN
- Setting AINEN to "0"
- Changing AMD (except a forced stop by setting AMD to "00")
- Setting ADRS to "1"
racy of AD conversion that you do not execute input/output instructions during AD conversion. Additionally, do not input
widely varying signals into the ports adjacent to analog input pins.
after returning to NORMAL mode, you must reconfigure ADRS, AMD and AINEN.
Read/Write
Bit Symbol
AINEN
After reset
ADRS
SAIN
AMD
AD conversion start
AD operating mode
Analog input control
Analog input channel select
ADRS
R/W
7
0
6
0
AMD
R/W
5
0
Page 295
0000:
0001:
0010:
0011:
0100:
0101:
0110:
1000:
1001:
1010:
1011:
1100:
1101:
0111:
1110:
1111:
00:
01:
10:
11:
0:
1:
0:
1:
AD conversion start
AD operation disable, forcibly stop AD operation
Single mode
Reserved
Repeat mode
Analog input disable
Analog input enable
AIN0
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
AIN7
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
-
AINEN
R/W
4
0
3
0
2
0
SAIN
R/W
1
0
TMP89FM42
0
0