tmp89fm42 TOSHIBA Semiconductor CORPORATION, tmp89fm42 Datasheet - Page 72

no-image

tmp89fm42

Manufacturer Part Number
tmp89fm42
Description
8 Bit Microcontroller
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
tmp89fm42AUG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42LUG
Manufacturer:
ST
Quantity:
500
Part Number:
tmp89fm42LUG
Manufacturer:
TOSHIBA
Quantity:
745
Part Number:
tmp89fm42LUG
Manufacturer:
TOSHIBA
Quantity:
1 000
Part Number:
tmp89fm42LUG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG
Manufacturer:
PROCONN
Quantity:
3 705
Part Number:
tmp89fm42UG
Manufacturer:
TOSHIBA/PBF
Quantity:
29
Part Number:
tmp89fm42UG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG
0
Company:
Part Number:
tmp89fm42UG
Quantity:
15 795
Company:
Part Number:
tmp89fm42UG
Quantity:
2 400
Part Number:
tmp89fm42UG(C
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG(C,JZ)
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG(CZHZ)
0
Part Number:
tmp89fm42UG(JZ)
Manufacturer:
Toshiba
Quantity:
10 000
3.5 Interrupt Sequence
3. Interrupt Control Circuit
RA003
Example :Save/store register using data transfer instructions
Example :Saving/restoring registers, using an instruction for transfer with data memory (with the main task using the regis-
Figure 3-4 Saving/Restoring General-purpose Registers under Interrupt Processing
3.5.3.2
3.5.3.3
ter bank BANK0)
PINTxx:
PINTxx:
purpose registers at a time. The register bank function saves (switches) the general-purpose registers by
executing a register bank manipulation instruction (such as LD RBS,1) at the beginning of an interrupt
service task. It is unnecessary to re-execute the register bank manipulation instruction at the end of the
interrupt service task because executing the RETI instruction makes a return automatically to the register
bank that was being used by the main task according to the content of the PSW.
Using data transfer instructions
Using a register bank to save/restore general-purpose registers
To save only a specific register without nested interrupts, data transfer instructions are available.
In non-multiple interrupt handling, the register bank function can be used to save/restore the general-
Note: Two register banks (BANK0 and BANK1) are available. Each bank consists of 8-bit general-purpose
registers (W, A, B, C, D, E, H, and L) and 16-bit general-purpose registers (IX and IY).
LD
Interrupt processing
LD
RETI
LD
Interrupt processing
RETI
Main task
Interrupt acceptance Interrupt
Interrupt return
(GSAVA), A
A, (GSAVA)
RBS, 1
Page 58
service task
; Save A register
; Restore A register
; RETURN
; Switches to the register bank BANK1
; RETURN
(Makes a return automatically to BANK0 that
was being used by the main task when the
PSW is restored)
Saving
registers
Restoring
registers