tmp89fm42 TOSHIBA Semiconductor CORPORATION, tmp89fm42 Datasheet - Page 361

no-image

tmp89fm42

Manufacturer Part Number
tmp89fm42
Description
8 Bit Microcontroller
Manufacturer
TOSHIBA Semiconductor CORPORATION
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
tmp89fm42AUG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42LUG
Manufacturer:
ST
Quantity:
500
Part Number:
tmp89fm42LUG
Manufacturer:
TOSHIBA
Quantity:
745
Part Number:
tmp89fm42LUG
Manufacturer:
TOSHIBA
Quantity:
1 000
Part Number:
tmp89fm42LUG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG
Manufacturer:
PROCONN
Quantity:
3 705
Part Number:
tmp89fm42UG
Manufacturer:
TOSHIBA/PBF
Quantity:
29
Part Number:
tmp89fm42UG
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG
0
Company:
Part Number:
tmp89fm42UG
Quantity:
15 795
Company:
Part Number:
tmp89fm42UG
Quantity:
2 400
Part Number:
tmp89fm42UG(C
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG(C,JZ)
Manufacturer:
TOSHIBA/东芝
Quantity:
20 000
Part Number:
tmp89fm42UG(CZHZ)
0
Part Number:
tmp89fm42UG(JZ)
Manufacturer:
Toshiba
Quantity:
10 000
RA002
Table 22-14 Flash Memory Status Output Commands
BOOT
ROM
22.8.7 Flash memory status output command (0xC3)
Note 1: "xxH u 3" means that the device goes into an idle state after transmitting 3 bytes of xxH.
Note 2: For detailed information on the status code 1, refer to "22.8.7.1 Flash memory status code".
1st byte
2nd byte
3rd byte
4th byte
5th byte
6th byte
7th byte
8th byte
9th byte
10th byte
11th byte
12th byte
13th byte
14th byte
Transfer byte
Table 22-14 shows the flash memory status output commands.
Matching data 1 (0x86 or 0x30)
-
Matching data 2 (0x79 or 0xCF)
-
Operation command data (0xC3)
-
(Wait for the next operation command data)
Transfer data from the external controller to
TMP89FM42
Page 347
Automatic adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate after adjustment
Baud rate
-(Automatic baud rate adjustment)
OK: Echo back data (0x86 or 0x30)
Error: No data transmitted
-
OK: Echo back data (0x79 or 0xCF)
Error: No data transmitted
-
OK: Echo back data (0xC3)
Error: 0xA1 u 3, 0xA3 u 3, 0x63 u 3 (note 1)
0x3A
0x04
0x00 to 0x7F
0x00
0x00
0x00
Checksum
(complement of 2 of the sum total from 9th
through 12th bytes)
-
Transfer data from TMP89FM42 to the exter-
nal controller
Start mark
Byte count
(from 9th through 12th bytes)
Status code 1
Reserved
Reserved
Reserved
TMP89FM42