s3c2410a Samsung Semiconductor, Inc., s3c2410a Datasheet - Page 113

no-image

s3c2410a

Manufacturer Part Number
s3c2410a
Description
16/32-bit Risc Arm Microprocessor
Manufacturer
Samsung Semiconductor, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
s3c2410a-20
Manufacturer:
SAMSUNG
Quantity:
15 995
Part Number:
s3c2410a-20
Quantity:
1 238
Part Number:
s3c2410a-20
Manufacturer:
SUNMNG
Quantity:
2 000
Company:
Part Number:
s3c2410a-20
Quantity:
130
Part Number:
s3c2410a-20-Y080
Manufacturer:
SAMSUNG
Quantity:
2 890
Part Number:
s3c2410a-20-Y0R0
Manufacturer:
SAMSUNG
Quantity:
523
Part Number:
s3c2410a20-Y080
Manufacturer:
SAMSUNG/三星
Quantity:
20 000
Company:
Part Number:
s3c2410a20-YO80
Quantity:
12 000
Company:
Part Number:
s3c2410a20-YO8N
Quantity:
1 619
S3C2410A
ARM INSTRUCTION SET
USE OF R15
Write-back must not be specified if R15 is specified as the base register (Rn). When using R15 as the base register
you must remember it contains an address 8 bytes on from the address of the current instruction.
R15 must not be specified as the register offset (Rm).
When R15 is the source register (Rd) of a register store (STR) instruction, the stored value will be address of the
instruction plus 12.
Restriction on the use of base register
When configured for late aborts, the following example code is difficult to unwind as the base register, Rn, gets
updated before the abort handler starts. Sometimes it may be impossible to calculate the initial value.
After an abort, the following example code is difficult to unwind as the base register, Rn, gets updated before the
abort handler starts. Sometimes it may be impossible to calculate the initial value.
EXAMPLE:
LDR
R0,[R1],R1
Therefore a post-indexed LDR or STR where Rm is the same register as Rn should not be used.
DATA ABORTS
A transfer to or from a legal address may cause problems for a memory management system. For instance, in a
system which uses virtual memory the required data may be absent from main memory. The memory manager can
signal a problem by taking the processor ABORT input HIGH whereupon the Data Abort trap will be taken. It is up to
the system software to resolve the cause of the problem, then the instruction can be restarted and the original
program continued.
INSTRUCTION CYCLE TIMES
Normal LDR instructions take 1S + 1N + 1I and LDR PC take 2S + 2N +1I incremental cycles, where S,N and I are
defined as sequential (S-cycle), non-sequential (N-cycle), and internal (I-cycle), respectively. STR instructions take
2N incremental cycles to execute.
3-31