s3c2410a Samsung Semiconductor, Inc., s3c2410a Datasheet - Page 278

no-image

s3c2410a

Manufacturer Part Number
s3c2410a
Description
16/32-bit Risc Arm Microprocessor
Manufacturer
Samsung Semiconductor, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
s3c2410a-20
Manufacturer:
SAMSUNG
Quantity:
15 995
Part Number:
s3c2410a-20
Quantity:
1 238
Part Number:
s3c2410a-20
Manufacturer:
SUNMNG
Quantity:
2 000
Company:
Part Number:
s3c2410a-20
Quantity:
130
Part Number:
s3c2410a-20-Y080
Manufacturer:
SAMSUNG
Quantity:
2 890
Part Number:
s3c2410a-20-Y0R0
Manufacturer:
SAMSUNG
Quantity:
523
Part Number:
s3c2410a20-Y080
Manufacturer:
SAMSUNG/三星
Quantity:
20 000
Company:
Part Number:
s3c2410a20-YO80
Quantity:
12 000
Company:
Part Number:
s3c2410a20-YO8N
Quantity:
1 619
I/O PORTS
9-24
FLTEN23
FLTEN22
FLTEN21
FLTEN20
FLTEN19
FLTEN18
FLTEN17
FLTEN16
EXTINT2
EINT23
EINT22
EINT21
EINT20
EINT19
EINT18
EINT17
EINT16
[30:28]
[26:24]
[22:20]
[18:16]
[14:12]
[10:8]
[6:4]
[2:0]
[31]
[27]
[23]
[19]
[15]
[11]
Bit
[7]
[3]
Filter Enable for EINT23
Set the signaling method of the EINT23.
000 = Low level 001 = High level
10x = Rising edge triggered
Filter Enable for EINT22
Set the signaling method of the EINT22.
000 = Low level 001 = High level
10x = Rising edge triggered
Filter Enable for EINT21
Set the signaling method of the EINT21.
000 = Low level 001 = High level
10x = Rising edge triggered
Filter Enable for EINT20
Set the signaling method of the EINT20.
000 = Low level 001 = High level
10x = Rising edge triggered
Filter Enable for EINT19
Set the signaling method of the EINT19.
000 = Low level 001 = High level
10x = Rising edge triggered
Filter Enable for EINT18
Set the signaling method of the EINT18.
000 = Low level 001 = High level
10x = Rising edge triggered
Filter Enable for EINT17
Set the signaling method of the EINT17.
000 = Low level 001 = High level
10x = Rising edge triggered
Filter Enable for EINT16
Set the signaling method of the EINT16.
000 = Low level 001 = High level
10x = Rising edge triggered
0 = Disable
0 = Disable
0 = Disable
0 = Disable
0 = Disable
0 = Disable
0 = Disable
0 = Disable
Description
01x = Falling edge triggered
01x = Falling edge triggered
01x = Falling edge triggered
01x = Falling edge triggered
01x = Falling edge triggered
01x = Falling edge triggered
01x = Falling edge triggered
01x = Falling edge triggered
11x = Both edge triggered
11x = Both edge triggered
11x = Both edge triggered
11x = Both edge triggered
11x = Both edge triggered
11x = Both edge triggered
11x = Both edge triggered
11x = Both edge triggered
1= Enable
1= Enable
1= Enable
1= Enable
1= Enable
1= Enable
1= Enable
1= Enable
S3C2410A