R0K572115S000BE Renesas Electronics America, R0K572115S000BE Datasheet - Page 164

no-image

R0K572115S000BE

Manufacturer Part Number
R0K572115S000BE
Description
KIT STARTER FOR SH7211
Manufacturer
Renesas Electronics America
Series
Renesas Starter Kits (RSK)r
Type
Microcontrollerr
Datasheets

Specifications of R0K572115S000BE

Contents
CPU Board, LCD Display Module, E8 Emulator, Cable, QuickStart Guide and CD-ROM
For Use With/related Products
SH7211
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
6.8.3
If an interrupt occurs and usage of the register banks is enabled for the interrupt accepted by the
CPU in a state where saving has been performed to all register banks, automatic saving to the
stack is performed instead of register bank saving if the BOVE bit in the bank number register
(IBNR) is cleared to 0. If the BOVE bit in IBNR is set to 1, register bank overflow exception
occurs and data is not saved to the stack.
Save and restore operations when using the stack are as follows:
(1)
1. The status register (SR) and program counter (PC) are saved to the stack during interrupt
2. The contents of the banked registers (R0 to R14, GBR, MACH, MACL, and PR) are saved to
3. The register bank overflow bit (BO) in SR is set to 1.
4. The bank number bit (BN) value in the bank number register (IBNR) remains set to the
(2)
When the RESBANK (restore from register bank) instruction is executed with the register bank
overflow bit (BO) in SR set to 1, the CPU operates as follows:
1. The contents of the banked registers (R0 to R14, GBR, MACH, MACL, and PR) are restored
2. The bank number bit (BN) value in the bank number register (IBNR) remains set to the
Rev. 3.00 Mar. 04, 2009 Page 138 of 1168
REJ09B0344-0300
exception handling.
the stack. The registers are saved to the stack in the order of MACL, MACH, GBR, PR, R14,
R13, …, R1, and R0.
maximum value of 15.
from the stack. The registers are restored from the stack in the order of R0, R1, …, R13, R14,
PR, GBR, MACH, and MACL.
maximum value of 15.
Saving to Stack
Restoration from Stack
Save and Restore Operations after Saving to All Banks

Related parts for R0K572115S000BE