Contents
CPU Board, LCD Display Module, E8 Emulator, Cable, QuickStart Guide and CD-ROM
For Use With/related Products
SH7211
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
18.5
18.5.1
Operation of the D/A converter can be disabled or enabled using the standby control register. The
initial setting is for operation of the D/A converter to be halted. Register access is enabled by
canceling module standby mode. For details, see section 23, Power-Down Modes.
18.5.2
When this LSI enters software standby mode with D/A conversion enabled, the D/A outputs are
retained, and the analog power supply current is equal to as during D/A conversion. If the analog
power supply current needs to be reduced in software standby mode, clear the DAOE0, DAOE1,
and DAE bits to 0 to disable the D/A outputs.
18.5.3
The reliability of this LSI may be adversely affected if the following voltage ranges are exceeded.
1. AVcc and AVss input voltages
2. Setting range of AVREF input voltage
Input voltages AVcc and AVss should be Vcc ≤ AVcc ≤ 5.0 V ± 0.5 V and AVss = Vss. Do
not leave the AVcc and AVss pins open when the A/D converter or D/A converter is not in use
and in software standby mode. When not in use, connect AVcc to the power supply (VccQ)
and AVss to the ground (VssQ).
Set the voltage range of the AVREF pin as AVREF = AVcc ± 0.3 V when the A/D converter
or D/A converter is used, or as AVREF = AVcc when no A/D converter or D/A converter is
used.
Usage Notes
Module Standby Mode Setting
D/A Output Hold Function in Software Standby Mode
Setting Analog Input Voltage