UPD70F3765GF-GAT-AX Renesas Electronics America, UPD70F3765GF-GAT-AX Datasheet - Page 599

no-image

UPD70F3765GF-GAT-AX

Manufacturer Part Number
UPD70F3765GF-GAT-AX
Description
MCU 32BIT V850ES/JX3-H 128-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Hr
Datasheet

Specifications of UPD70F3765GF-GAT-AX

Core Processor
RISC
Core Size
32-Bit
Speed
48MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART, USB
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
96
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3765GF-GAT-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
V850ES/JG3-H, V850ES/JH3-H
R01UH0042EJ0400 Rev.4.00
Sep 30, 2010
(3) Output waveform in vicinity of 0% and 100% output
<1> The valley interrupt selects 100% ←→ 0% or 0% ←→ 100% output.
<2> The crest interrupt selects 100% ←→ 0% output.
If an interrupt is generated because the value of the 16-bit counter matches the value of the compare register while
dead time is being counted, the dead-time counter is cleared and starts its count operation again.
The output waveform of dead-time control in the vicinity of 0% and 100% output is shown below.
Figure 11-11. PWM Output Waveform from 0% to 100% and from 100% to 0% (With Dead Time)
Output can be selected from 100% ←→ 0% or 0% ←→ 100% immediately after the timer has been
started.
The crest interrupt selects 100% → 0% output by using the timer output forcible raising function and by a
match between the 16-bit counter value and the TAB1CCR0 register value.
of timer output
buffer register
Forced timing
TAB1CCR1
TAB1CCR0
TOAB1T1
TOAB1B1
pin output
pin output
register
register
counter
CCR1
16-bit
0000H
<1>
0000H
0000H
output
100%
M + 1
<1>
0% output
M + 1
<2>
0000H
0000H
output
100%
M
CHAPTER 11 MOTOR CONTROL FUNCTION
<2>
M + 1
0% output
M + 1
<1>
0000H
0000H
output
100%
Page 599 of 1509