UPD70F3765GF-GAT-AX Renesas Electronics America, UPD70F3765GF-GAT-AX Datasheet - Page 838

no-image

UPD70F3765GF-GAT-AX

Manufacturer Part Number
UPD70F3765GF-GAT-AX
Description
MCU 32BIT V850ES/JX3-H 128-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Hr
Datasheet

Specifications of UPD70F3765GF-GAT-AX

Core Processor
RISC
Core Size
32-Bit
Speed
48MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART, USB
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
96
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
2.85 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3765GF-GAT-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
V850ES/JG3-H, V850ES/JH3-H
19.6 I
generated on the I
data).
low-level period can be extended and a wait state can be inserted (n = 0 to 2).
19.6.1 Start condition
start condition for the SCL0n and SDA0n pins is a signal that the master device outputs to the slave device when starting a
serial transfer. The slave device can detect the start condition (n = 0 to 2).
= 1). When a start condition is detected, the IICSn.STDn bit is set (1) (n = 0 to 2).
R01UH0042EJ0400 Rev.4.00
Sep 30, 2010
The following section describes the I
The transfer timing for the “start condition”, “address”, “transfer direction specification”, “data”, and “stop condition”
The master device generates the start condition, slave address, and stop condition.
ACK can be generated by either the master or slave device (normally, it is generated by the device that receives 8-bit
The serial clock (SCL0n) is continuously output by the master device. However, in the slave device, the SCL0n pin’s
A start condition is met when the SCL0n pin is high level and the SDA0n pin changes from high level to low level. The
A start condition is output when the IICCn.STTn bit is set (1) after a stop condition has been detected (IICSn.SPDn bit
Caution When the IICCn.IICEn bit of the V850ES/JG3-H and V850ES/JH3-H is set to 1 while other devices are
2
C Bus Definitions and Control Methods
communicating, the start condition may be detected depending on the status of the communication
line. Be sure to set the IICCn.IICEn bit to 1 when the SCL0n and SDA0n lines are high level.
SDA0n
SCL0n
2
C bus’s serial data bus is shown below.
Start
condition
Address
1 to 7
Figure 19-7. I
SDA0n
SCL0n
2
C bus’s serial data communication format and the signals used by the I
R/W
8
Figure 19-8. Start Condition
H
ACK
2
9
C Bus Serial Data Transfer Timing
1 to 8
Data
ACK
9
1 to 8
Data
ACK
9
Stop
condition
CHAPTER 19 I
Page 838 of 1509
2
C bus.
2
C BUS

Related parts for UPD70F3765GF-GAT-AX