Description
Encoder Connector ABS Motor
Manufacturer
Omron
Datasheet

Specifications of R88A-CNG01R

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
R88D-GT04L/-GT08H/-GT10H/-GT15H/-GT20H/-GT30H/-GT50H
R88D-GT75H
If an External Regeneration Resistor is necessary, remove the short-circuit bar between B2 and B3,
and then connect the External Regeneration Resistor between B1 and B2 as shown in the diagram
below.
If an External Regeneration Resistor is necessary, connect it between B1 and B2 as shown in the
diagram below.
Precautions
for Correct Use
Precautions
for Correct Use
Servo Drive
Servo Drive
B1
B3
B2
B1
B2
Remove the short-circuit bar between B2 and B3.
Regeneration
Connect the thermal switch output so that the main circuit power supply is
shut OFF when the contacts open.
When using multiple External Regeneration Resistors, connect each
thermal switch in series.
The resistor may be damaged by burning, or cause fire if it is used without
setting up a power supply shutoff sequence using the output from the
thermal switch.
Connect the thermal switch output so that the main circuit power supply is
shut OFF when the contacts open.
When using multiple External Regeneration Resistors, connect each
thermal switch in series.
The resistor may be damaged by burning, or cause fire if it is used without
setting up a power supply shutoff sequence using the output from the
thermal switch.
External
Resistor
θ>
θ>
External Regeneration
Resistor
Thermal Switch Output
Thermal Switch Output
4-4 Regenerative Energy Absorption
4-50