6-4 Setting the Mode
Copy Mode
6-25
Key operation
Key operation
Key operation
Copying from the Servo Drive to the Parameter Unit
1. Displaying Copy Mode
2. Executing Copying
3. Returning to Copy Mode
In Copy Mode, user parameters set in the Servo Drive can be copied to the Parameter Unit, and
user parameters stored in the Parameter Unit can be copied to the Servo Drive.
This function can be used to easily set the same user parameters for more than one Servo Drive.
Precautions
for Correct Use
ekekpkcklkr
-k-
Display example
Display example
Display example
If “Error” is displayed before completion, repeat the procedure from the
beginning. Press the Data key to clear the error.
Do not disconnect the Parameter Unit from the Servo Drive while copying
is being performed. If the Parameter Unit is disconnected, connect it and
then repeat the procedure from the beginning.
If errors are repeatedly displayed, the following may be the cause: cable
disconnection, connector contact failure, incorrect operation due to noise,
or EEPROM fault in the Parameter Unit.
The item set for the Default Display (Pn01) is displayed.
Press the Data key to display Monitor Mode.
Press the Mode key five times to display Copy Mode.
Press the Data key to enter Copy Mode.
Press and hold the Increment key until “EEPCLR” is displayed.
The bar indicator will increase when the key is pressed for 3 s or longer.
The bar indicator will increase.
Initialization of the EEPROM in the Parameter Unit will start.
This display indicates a normal completion.
Press the Data key to return to Copy Mode.