R88A-CNG01R Omron, R88A-CNG01R Datasheet - Page 303

no-image

R88A-CNG01R

Manufacturer Part Number
R88A-CNG01R
Description
Encoder Connector ABS Motor
Manufacturer
Omron
Datasheet

Specifications of R88A-CNG01R

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
5-9 Overrun Limit
Function
Parameters Requiring Settings
Operating Conditions
Parameter No.
Operating mode
Pn26
Others
• The Servomotor can be stopped with an alarm for an overrun limit error (alarm code 34) if the
• This can be used to prevent impact on the edges of the machine because of Servomotor
• The overrun limit will operate under the following conditions.
Conditions for Clearing the Position Command Input Range
The position command input range will be cleared to zero under the following conditions.
• The power supply is turned ON.
• The position deviation is cleared. (The deviation counter clearing is enabled and drive prohibit
• Normal Mode Autotuning starts or ends.
Servomotor exceeds the allowable operating range set in the Overrun Limit Setting (Pn26) with
respect to the position command input.
oscillation.
input is enabled by setting the Stop Selection for Drive Prohibition Input (Pn66) to 2.)
Position Control Mode is used.
Pn02 = 0: Position control
Pn02 = 3: First control mode for position/speed control
Pn02 = 4: First control mode for position/torque control
Overrun Limit Setting
1.The servo is ON.
2.The Overrun Limit Setting (Pn26) is not 0.
3.The allowable operating range for both forward and reverse is within 2147483647 after the po-
sition command input range is cleared to zero.
If the condition 1 above is not met, the Overrun Limit Setting will be disabled until the conditions
for clearing the position command input range are satisfied, as described below.
If the conditions 1 and 2 above are not met, the position command input range will be cleared to
zero.
Parameter name
Conditions under which the overrun limit will operate
Set the Servomotor’s allowable operating range for
the position command input range.
An overrun limit error (alarm code 34) will occur if the
set value is exceeded.
Explanation
5-9 Overrun Limit
Reference
page
5-64
5-18
5

Related parts for R88A-CNG01R