EVB9S12XEP100 Freescale Semiconductor, EVB9S12XEP100 Datasheet - Page 1120

BOARD EVAL FOR MC9S12XEP100

EVB9S12XEP100

Manufacturer Part Number
EVB9S12XEP100
Description
BOARD EVAL FOR MC9S12XEP100
Manufacturer
Freescale Semiconductor
Type
MCUr
Datasheet

Specifications of EVB9S12XEP100

Contents
Module and Misc Hardware
Processor To Be Evaluated
MC9S12XEP100
Data Bus Width
16 bit
Interface Type
RS-232
Silicon Manufacturer
Freescale
Core Architecture
S12
Core Sub-architecture
S12
Silicon Core Number
MC9S12
Silicon Family Name
S12XE
Rohs Compliant
Yes
For Use With/related Products
MC9S12XEP100
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Chapter 28 768 KByte Flash Module (S12XFTM768K4V2)
28.4.2.6
The Program P-Flash operation will program a previously erased phrase in the P-Flash memory using an
embedded algorithm.
Upon clearing CCIF to launch the Program P-Flash command, the Memory Controller will program the
data words to the supplied global address and will then proceed to verify the data words read back as
expected. The CCIF flag will set after the Program P-Flash operation has completed.
1120
1. As defined by the memory map for FTM1024K5.
FERSTAT
Register
FSTAT
Program P-Flash Command
A P-Flash phrase must be in the erased state before being programmed.
Cumulative programming of bits within a Flash phrase is not allowed.
1. Global address [2:0] must be 000
CCOBIX[2:0]
Table 28-43. Program P-Flash Command FCCOB Requirements
MGSTAT1
MGSTAT0
EPVIOLIF
ACCERR
Error Bit
FPVIOL
000
001
010
011
100
101
Table 28-42. Load Data Field Command Error Handling
MC9S12XE-Family Reference Manual , Rev. 1.23
Global address [15:0] of phrase location to be programmed
Set if CCOBIX[2:0] != 101 at command launch
Set if command not available in current mode (see
Set if an invalid global address [22:0] is supplied
Set if a misaligned phrase address is supplied (global address [2:0] != 000)
Set if a Load Data Field command sequence is currently active and the selected
block has previously been selected in the same command sequence
Set if a Load Data Field command sequence is currently active and global
address [17:0] does not match that previously supplied in the same command
sequence
Set if the global address [22:0] points to a protected area
None
None
None
0x06
CAUTION
Word 0 program value
Word 1 program value
Word 2 program value
Word 3 program value
FCCOB Parameters
Error Condition
Global address [22:16] to
identify P-Flash block
(1)
Table
28-30)
(1)
Freescale Semiconductor

Related parts for EVB9S12XEP100