HD6417144F50V Renesas Electronics America, HD6417144F50V Datasheet - Page 494

IC SUPERH MCU ROMLESS 112QFP

HD6417144F50V

Manufacturer Part Number
HD6417144F50V
Description
IC SUPERH MCU ROMLESS 112QFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7144r
Datasheet

Specifications of HD6417144F50V

Core Processor
SH-2
Core Size
32-Bit
Speed
50MHz
Connectivity
EBI/EMI, I²C, SCI
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
74
Program Memory Type
ROMless
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
112-QFP
For Use With
HS0005KCU11H - EMULATOR E10A-USB H8S(X),SH2(A)EDK7145 - DEV EVALUATION KIT SH7145
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417144F50V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
13. Serial Communication Interface (SCI)
Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the ORER,
FER, PER, and RDRF bits to 0 before resuming reception. Figure 13.19 shows a sample flowchart
for serial data reception.
An overrun error occurs or synchronous clocks are output until the RE bit is cleared to 0 when an
internal clock is selected and only receive operation is possible. When reception will be carried out
in a unit of one frame, be sure to carry out a dummy transmission with only one frame by the
simultaneous transmit and receive operations at the same time.
Rev.4.00 Mar. 27, 2008 Page 448 of 882
REJ09B0108-0400
[3]
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
Clear ORER flag in SSR to 0
Read ORER flag in SSR
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Overrun error processing
Figure 13.19 Sample Serial Reception Flowchart
All data received?
Error processing
Start reception
Initialization
ORER = 1
RDRF = 1
<End>
<End>
Yes
Yes
No
(Continued below)
Error processing
Yes
[2]
[1]
[3]
[4]
[5]
[1] SCI initialization:
[2] [3] Receive error processing:
[4] SCI status check and receive data
[5] Serial reception continuation
Set the RxD pin using the PFC.
If a receive error occurs, read the
ORER flag in SSR, and after
performing the appropriate error
processing, clear the ORER flag to 0.
Transfer cannot be resumed if the
ORER flag is set to 1.
read:
Read SSR and check that the RDRF
flag is set to 1, then read the receive
data in RDR and clear the RDRF flag
to 0.
Transition of the RDRF flag from 0 to 1
can also be identified by an RXI
interrupt.
procedure:
To continue serial reception, before
the MSB (bit 7) of the current frame is
received, reading the RDRF flag,
reading RDR, and clearing the RDRF
flag to 0 should be finished. The
RDRF flag is cleared automatically
when the DMAC or DTC is activated
by a receive data full interrupt (RXI)
request and the RDR value is read.

Related parts for HD6417144F50V