HD64F2145BTE20 Renesas Electronics America, HD64F2145BTE20 Datasheet - Page 441

IC H8S MCU FLASH 256K 100-QFP

HD64F2145BTE20

Manufacturer Part Number
HD64F2145BTE20
Description
IC H8S MCU FLASH 256K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2100r
Datasheets

Specifications of HD64F2145BTE20

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, IrDA, SCI, X-Bus
Peripherals
PWM, WDT
Number Of I /o
74
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
PER ∨ FER ∨ ORER = 1
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Read ORER, PER, and
All data received?
FER flags in SSR
Start reception
Figure 15.9 Sample Serial Reception Flowchart (1)
Initialization
RDRF = 1
<End>
Yes
Yes
No
(Continued on next page)
Error processing
Section 15 Serial Communication Interface (SCI and IrDA)
Yes
[1]
[2]
[4]
[5]
[3]
[1] SCI initialization:
[2] [3] Receive error processing and break
[4] SCI status check and receive data read:
[5] Serial reception continuation procedure:
Legend:
: Logical OR
Rev. 3.00 Mar 21, 2006 page 385 of 788
The RxD pin is automatically
designated as the receive data input
pin.
detection:
If a receive error occurs, read the
ORER, PER, and FER flags in SSR to
identify the error. After performing the
appropriate error processing, ensure
that the ORER, PER, and FER flags are
all cleared to 0. Reception cannot be
resumed if any of these flags are set to
1. In the case of a framing error, a
break can be detected by reading the
value of the input port corresponding to
the RxD pin.
Read SSR and check that RDRF = 1,
then read the receive data in RDR and
clear the RDRF flag to 0. Transition of
the RDRF flag from 0 to 1 can also be
identified by an RXI interrupt.
To continue serial reception, before the
stop bit for the current frame is
received, read the RDRF flag, read
RDR, and clear the RDRF flag to 0.
However, the RDRF flag is cleared
automatically when the DTC is initiated
by an RXI interrupt and reads data from
RDR.
REJ09B0300-0300