HD64F2145BTE20 Renesas Electronics America, HD64F2145BTE20 Datasheet - Page 455

IC H8S MCU FLASH 256K 100-QFP

HD64F2145BTE20

Manufacturer Part Number
HD64F2145BTE20
Description
IC H8S MCU FLASH 256K 100-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2100r
Datasheets

Specifications of HD64F2145BTE20

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, IrDA, SCI, X-Bus
Peripherals
PWM, WDT
Number Of I /o
74
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
[3]
No
No
Read receive data in RDR and
clear RDRF flag in SSR to 0
Clear ORER flag in SSR to 0
Read ORER flag in SSR
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Overrun error processing
All data received?
Error processing
Start reception
Initialization
Figure 15.19 Sample Serial Reception Flowchart
ORER = 1
RDRF = 1
<End>
<End>
Yes
Yes
No
(Continued below)
Error processing
Section 15 Serial Communication Interface (SCI and IrDA)
Yes
[2]
[1]
[3]
[4]
[5]
[1] SCI initialization:
[2] [3] Receive error processing:
[4] SCI status check and receive data
[5] Serial reception continuation
Rev. 3.00 Mar 21, 2006 page 399 of 788
The RxD pin is automatically
designated as the receive data input
pin.
If a receive error occurs, read the
ORER flag in SSR, and after
performing the appropriate error
processing, clear the ORER flag to 0.
Transfer cannot be resumed if the
ORER flag is set to 1.
read:
Read SSR and check that the RDRF
flag is set to 1, then read the receive
data in RDR and clear the RDRF flag
to 0.
Transition of the RDRF flag from 0 to 1
can also be identified by an RXI
interrupt.
procedure:
To continue serial reception, before
the MSB (bit 7) of the current frame is
received, reading the RDRF flag,
reading RDR, and clearing the RDRF
flag to 0 should be finished.
However, the RDRF flag is cleared
automatically when the DTC is
initiated by a receive data full interrupt
(RXI) and reads data from RDR.
REJ09B0300-0300

Related parts for HD64F2145BTE20