Specifications of R5F61662N50FPV

Core Processor
H8SX
Core Size
16/32-Bit
Speed
50MHz
Connectivity
EBI/EMI, I²C, IrDA, SCI, SmartCard, USB
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
92
Program Memory Size
384KB (384K x 8)
Program Memory Type
FLASH
Ram Size
40K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
R5F61662N50FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
5.7
There are two instructions that cause exception handling: trap instruction and illegal instruction.
5.7.1
Trap instruction exception handling starts when a TRAPA instruction is executed. Trap instruction
exception handling can be executed at all times in the program execution state. The trap
instruction exception handling is as follows:
1. The contents of PC, CCR, and EXR are saved in the stack.
2. The interrupt mask bit is updated and the T bit is cleared to 0.
3. An exception handling vector table address corresponding to the vector number specified in
A start address is read from the vector table corresponding to a vector number from 0 to 3, as
specified in the instruction code.
Table 5.8 shows the state of CCR and EXR after execution of trap instruction exception handling.
Table 5.8
[Legend]
1: Set to 1
0: Cleared to 0
: Retains the previous value.
Interrupt Control Mode
0
2
the TRAPA instruction is generated, the start address of the exception service routine is loaded
from the vector table to PC, and program execution starts from that address.
Instruction Exception Handling
Trap Instruction
States of CCR and EXR after Trap Instruction Exception Handling
I
1
1
CCR
UI
Rev. 2.00 Sep. 16, 2009 Page 97 of 1036
I2 to I0
Section 5 Exception Handling
EXR
REJ09B0414-0200
T
0