Serial Over LAN—MPCBL0050
9.8.1.4
Note:
September 2007
Order Number: 318146-001
Execute the reference_cfg Script
The following apply to commands in the three procedures in step 2, below:
1. For Red Hat Enterprise Linux only: Before using the reference_cfg script, start the
2. Choose one of the three interfaces below to execute the reference_cfg script. It
IPMI drivers. For MontaVista, the IPMI drivers start automatically.
Start IPMI driver by issuing the following commands:
does not matter which interface is chosen. The reference_cfg script can be
executed through any of these interfaces.
— For MontaVista 4.0:
— For Red Hat RHEL 4U4:
— For Red Hat RHEL 5:
— When the SOL client and SOL target are behind the same gateway, the
— The “-l <SOL Target IPMB Addr>” parameter needs to be entered as “-l 0xNN”,
— Script executed on the local SOL target blade payload. Communication is
— Script executed on the Intel CMM. Communication is from CMM to target
— Script executed on a remote computer. Communication is from the remote
# /etc/init.d/ipmi start
session only)
# chkconfig ipmi on
“<Gateway MAC Addr>” and “<Gateway IP Addr>” parameters can be omitted.
where NN is the IPMB address of the target blade. The IPMB address depends
upon the location of the target blade in the chassis. Refer to
of physical slot to IPMB address in Intel NetStructure
on page 232
chassis. Other chassis may have different IPMB addresses.
from host processor to local IPMC through the KCS interface.
Execute this command to configure SOL on the target blade:
blade through IPMB. This requires the MPCMM0001 or MPCMM0002 CMM and
firmware version 6.1.0.2779 or later.
a. FTP the /usr/bin/reference_cfg and /usr/lib/sbcutils/reference_funcs files to
the CMM /home/scripts directory. The CMM default IP address is 10.90.90.91.
If you cannot FTP to the CMM, at the CMM prompt, type
and comment out the root (# root). Then type
b. Execute the following command to the change the reference_cfg file
attributes:
c. Execute the following command to configure SOL on the target blade:
computer to the CMM through a LAN interface (RMPC), which is then bridged to
the target blade’s IPMC through the IPMB.
rpm -ivh sbcutils-1.X.X-X.i386-mv40.rpm
rpm -ivh sbcutils-1.X.X-X.i386-rhel4.rpm
rpm -ivh sbcutils-1.X.X-X.i386-rhel4.rpm
reference_cfg -I kcs -g -i <SOL Target IP Addr>
reference_cfg -I ipmb -g -i <SOL Target IP Addr>
-j <Gateway IP Addr> -n <Gateway MAC Addr>
-l <SOL Target IPMB Addr>
chmod 777 reference_cfg
for the IPMB address for each physical slot in an MPCHC0001
(this starts ipmi drivers by default on the next reboot)
(this starts ipmi drivers for this particular
Intel NetStructure
:wq!
®
MPCBL0050 Single Board Computer
®
to save the file.
MPCHC0001 14U Shelf”
Technical Product Specification
vi /etc/ftpusers
Table 79, “Mapping
173