MPCBL0050N02Q Intel, MPCBL0050N02Q Datasheet - Page 224

no-image

MPCBL0050N02Q

Manufacturer Part Number
MPCBL0050N02Q
Description
Manufacturer
Intel
Datasheet

Specifications of MPCBL0050N02Q

Lead Free Status / RoHS Status
Supplier Unconfirmed
Table 78.
Intel NetStructure
Technical Product Specification
224
®
Warning and error messages (Sheet 3 of 11)
E546
E700
E701
E702
E703
E704
E705
E706
E707
E708
Number
MPCBL0050 Single Board Computer
Requested information not supported on
the target
Unsupported firmware update mode
"%1". It must be one of %2
You must supply exactly one input
filename
Manufacturer ID mismatch! The supplied
input file is not intended for this target.
Product ID mismatch! The supplied input
file is not intended for this target.
Staged firmware updates are not
available at this time. Either the target
does not have that capability, or the
target is in direct firmware transfer
mode. Use -M direct or --mode direct to
perform a firmware upgrade.
Firmware rollback updates are not
supported for the specified target.
Preparation of the staging flash area
failed!
Capture of the rollback image failed!
Upload of the new staged image failed!
Message
This message should only be displayed if there is an
internal code error in which a FRU library operation is
called without a specification of what operation is to be
performed.
This error message is displayed when an unsupported
mode is supplied on the command line. The command-
line option is -M or --mode. %1 is replaced with what
was supplied, and %2 is replaced with the mode types
that are supported.
This error message is displayed when a HEX file
provided by Intel was not supplied on the command
line, or if there is more than one file or option specified
at the end of the command line.
This error message is displayed when the supplied HEX
file provided by Intel has a different manufacturer ID
for the target SBC. This can be displayed whether
performing a direct or staged firmware update.
This error message is displayed when the supplied HEX
file supplied by Intel has a different product ID for the
target SBC. This can be displayed whether performing
a direct or staged firmware update.
This error message is displayed when a staged
firmware update was requested, but the target IPMC
does not support them. This can only be displayed
when specifically requesting a staged update with
mode staged or -M staged.
This error message is displayed if the IPMC does not
support capturing a rollback image. This is more of a
safety measure, and can be overridden with
nocapturerb. This is only displayed if attempting a
staged firmware update.
This error message is displayed if an error occurred
while erasing the flash memory where the staging
image is to be written. Failure cases can be a flash
error, no permission, or a refused operation due to
another operation being performed on the same area.
The underlying library should supply a more descriptive
message indicating what specifically failed. This is only
displayed if attempting a staged firmware update.
This error message is displayed if an error occurred
while capturing the rollback image. Failure cases can
be a flash error, no permission, or a refused operation
due to another operation being performed on the same
area. The underlying library should supply a more
descriptive message indicating what specifically failed.
This is only displayed if attempting a staged firmware
update.
This error message is displayed if an error occurred
while writing the new staging image to the staging area
of flash memory. Failure cases can be a flash error, no
permission, or a refused operation due to another
operation being performed on the same area. The
underlying library should supply a more descriptive
message indicating what specifically failed. This is only
displayed if attempting a staged firmware update.
MPCBL0050—Firmware Update Utilities
Description
Order Number: 318146-001
September 2007