Note:
10.6.9.2
September 2007
Order Number: 318146-001
Current firmware version: 1.02.00
Current bootblock version: 1.01
Current staged firmware version: 1.02.00 (pending)
Current rollback firmware version: 1.02.00
This example output is only the beginning of the actual output. Notice that the “Current
staged firmware version” is pending.
Execute the following command to cancel any pending staged firmware updates:
The output of this command is:
Canceling any pending staged firmware updates.
All pending staged firmware updates have been canceled.
Program exiting!
Execute the -M info option again to see that the staged firmware updated has canceled:
Current firmware version: 1.02.00
Current bootblock version: 1.01
Current staged firmware version: <None>
Current rollback firmware version: 1.02.00
Cancel Staged Firmware Update via RMCP Bridging
To cancel a staged firmware update, a valid staged firmware update must already be
pending.
For RMCP bridging to work correctly, the Shelf Manager must be connected to the
network so that it can transmit TCP/IP traffic to and from the client. The interface
option must also be set to lan for RMCP bridging.
When using the sbcupdate utility over an RMCP bridge with the Intel NetStructure
MPCMM0001/0002 Chassis Management Module:
When using the sbcupdate utility over an RMCP bridge with a 3rd party Shelf Manager,
it is essential that communication between the target IPMC and a remote network node
via a shelf manager can be established. Refer to
privileges for RMCP bridging” on page 190
commands that must be forwarded to IPMB by the Shelf Manager.
The syntax of the command is:
For example:
• Check for a CMM firmware version of 6.1.1.x or higher.
• Transfer the /usr/share/doc/sbcutils/cmdPrivilege.ini file to both the active and
standby CMMs. Place cmdPrivelege.ini in the /etc/ directory on the CMMs. Then,
restart the RMCP servers. More details on this can be found in
“Configuring the Intel NetStructure
# sbcupdate -M info
# sbcupdate -M cancel
# sbcupdate -M info
# sbcupdate -I lan -M cancel -H <shelf_manager_ip_address>
# sbcupdate -I lan -M cancel -H 10.90.90.91 -U root
-U <username> -P <password> -t <target>
-P rootpass -t 0x8e
®
MPCMM0001/0002 CMM” on page
for more information on the required RMCP
Intel NetStructure
Table 74, “Required IPMI command
®
MPCBL0050 Single Board Computer
Technical Product Specification
Section 10.5.2,
191.
®