Setting Manual Rollback of the Firmware
Manual Rollback via KCS Interface
To force a manual rollback of the firmware, a valid rollback image must already be
present on the target management controller. If there is no firmware image in the
rollback area, the IPMC will go into direct update mode.
To run the command over the KCS interface, execute the following command:
If no interface is specified, KCS is assumed.
The output from this command should be similar to the following:
Registering a manual rollback of the firmware on the next IPMC reset.
The target management controller is being reset.
sbcupdate (W606) Please ignore any select timeout warnings. They are issued by
the Linux driver due to target reset and may be ignored.
IPMI message handler: BMC returned incorrect response. expected netfn 7 cmd 2.
got netfn 31 cmd a4
The target management controller has been reset.
Manual rollback of the firmware for the next IMPC reset has been registered.
Program exiting!
The “IPMI message handler: BMC returned incorrect response.” error message is to be
expected and may be ignored. This is a timeout error in response to warning (W606) as
seen in the output above.
Manual Rollback via RMCP Bridging
To force a manual rollback of the firmware, a valid rollback image must already be
present on the target management controller. If there is no firmware image in the
rollback area, the IPMC will go into direct update mode.
For RMCP bridging to work correctly, the Shelf Manager must be connected to the
network so that it can transmit TCP/IP traffic to and from the client. The interface
option must also be set to lan for RMCP bridging.
When using the sbcupdate utility over RMCP bridge with Intel NetStructure
MPCMM0001/0002 Chassis Management Module:
When using the sbcupdate utility over an RMCP bridge with a 3rd party Shelf Manager,
it is essential that communication between the target IPMC and a remote network node
via a shelf manager can be established. Refer to
privileges for RMCP bridging” on page 190
commands that must be forwarded to IPMB by the Shelf Manager.
The syntax of the command is:
For example:
• Check for a CMM firmware version of 6.1.1.x or higher.
• Transfer the /usr/share/doc/sbcutils/cmdPrivilege.ini file to both the active and
MPCBL0050 Single Board Computer
standby CMMs. Place cmdPrivelege.ini in the /etc/ directory on the CMMs. Then,
restart the RMCP servers. More details on this can be found in
“Configuring the Intel NetStructure
# sbcupdate -I kcs -M rollback
# sbcupdate -I lan -M rollback
-H <ip address of shelf manager> -U <RMCP_username>
-P <RMCP_password> -t <target>
®
MPCMM0001/0002 CMM” on page
for more information on the required RMCP
Table 74, “Required IPMI command
MPCBL0050—Firmware Update Utilities
Order Number: 318146-001
Section 10.5.2,
September 2007
191.