MPCBL0050N02Q Intel, MPCBL0050N02Q Datasheet - Page 211

no-image

MPCBL0050N02Q

Manufacturer Part Number
MPCBL0050N02Q
Description
Manufacturer
Intel
Datasheet

Specifications of MPCBL0050N02Q

Lead Free Status / RoHS Status
Supplier Unconfirmed
Firmware Update Utilities—MPCBL0050
10.6.14
Caution:
September 2007
Order Number: 318146-001
To update the RTM FRU over the KCS interface on the MPCBL0050 SBC, execute the
following command:
Full FRU Update via RMCP Bridging
To perform a full FRU update, use the supplied FRU file for your target IPMC. Staged
FRU updates are not supported, therefore it is not necessary to specify direct mode
(-M direct). To invoke full FRU update requires the --force-fru-update command.
Full FRU updates remove all system FRU information and replace it with FRU data from
a file. All variable data and modifications/additions performed by users, such as
product number or name change, asset tag change or customer MRA record additions
are overwritten.
For RMCP bridging to work correctly, the Shelf Manager must be connected to the
network so that it can transmit TCP/IP traffic to and from the client. The interface
option must also be set to lan for RMCP bridging.
When using the sbcupdate utility over an RMCP bridge with the Intel NetStructure
MPCMM0001/0002 Chassis Management Module:
When using the sbcupdate utility over an RMCP bridge with a 3rd party Shelf Manager,
it is essential that communication between the target IPMC and a remote network node
via a shelf manager can be established. Refer to
privileges for RMCP bridging” on page 190
commands that must be forwarded to IPMB by the Shelf Manager.
The command to update the IPMC FRU on the MPCBL0050 has the following syntax:
The command to update the RTM FRU on the MPCBL0050 has the following syntax:
An example of updating the IPMC FRU:
The following is an example of updating the RTM FRU:
The output from this command should be similar to the following:
• Check for a CMM firmware version of 6.1.1.x or higher.
• Transfer the /usr/share/doc/sbcutils/cmdPrivilege.ini file to both the active and
standby CMMs. Place cmdPrivelege.ini in the /etc/ directory on the CMMs. Then,
restart the RMCP servers. More details on this can be found in
“Configuring the Intel NetStructure
# sbcupdate -I kcs --force-fru-update --force-id
# sbcupdate -I kcs -t rtm --force-fru-update MPRTM0050_NNN.fru
# sbcupdate -I lan -H <shelf_manager_ip_address>
# sbcupdate -I lan -H <shelf_manager_ip_address>
# sbcupdate -I lan -H 10.90.90.91 -U root -P cmmrootpass
# sbcupdate -I lan -H 10.90.90.91 -U root -P cmmrootpass
MPCBL0050_NNN.fru
-U <RMCP_username> -P <RMCP_password> -t <target>
--force-fru-update MPCBL0050_NNN.fru
-U <RMCP_username> -P <RMCP_password>
-t <target>:rtm --force-fru-update MPRTM0050_NNN.fru
-t 0x8e --force-fru-update MPCBL0050_NNN.fru
-t 0x8e:rtm --force-fru-update MPRTM0050_NNN.fru
®
MPCMM0001/0002 CMM” on page
for more information on the required RMCP
Intel NetStructure
Table 74, “Required IPMI command
®
MPCBL0050 Single Board Computer
Technical Product Specification
Section 10.5.2,
191.
®
211