HD64F2676VFC33 Renesas Electronics America, HD64F2676VFC33 Datasheet - Page 759

IC H8S MCU FLASH 256K 144-QFP

HD64F2676VFC33

Manufacturer Part Number
HD64F2676VFC33
Description
IC H8S MCU FLASH 256K 144-QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2676VFC33

Core Processor
H8S/2600
Core Size
16-Bit
Speed
33MHz
Connectivity
IrDA, SCI
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
103
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 4x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
144-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2676VFC33
Manufacturer:
RENESAS
Quantity:
5 530
Part Number:
HD64F2676VFC33
Quantity:
9 520
Part Number:
HD64F2676VFC33
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F2676VFC33V
Manufacturer:
RENESAS
Quantity:
5 530
Part Number:
HD64F2676VFC33V
Manufacturer:
ROHM
Quantity:
750 000
Part Number:
HD64F2676VFC33V
Manufacturer:
RENESAS
Quantity:
120
Part Number:
HD64F2676VFC33V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
No
No
No
Figure 15.13 Sample Multiprocessor Serial Reception Flowchart (1)
Read ORER and FER flags in SSR
Read ORER and FER flags in SSR
Read receive data in RDR
Read receive data in RDR
Set MPIE bit in SCR to 1
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Read RDRF flag in SSR
FER
FER
All data received?
Start of reception
This station's ID?
Initialization
RDRF = 1?
RDRF = 1?
<End>
ORER = 1?
ORER = 1?
Yes
Yes
Yes
Yes
No
No
Section 15 Serial Communication Interface (SCI, IrDA)
Yes
No
Yes
[4]
[3]
[1]
[2]
Error handling
(Continued on
next page)
[5]
Rev. 3.00 Mar 17, 2006 page 707 of 926
[1]
[2]
[3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
ID reception cycle:
Set the MPIE bit in SCR to 1.
SCI status check, ID reception
and comparison:
Read SSR and check that the
RDRF flag is set to 1, then read
the receive data in RDR and
compare it with this station’s ID.
If the data is not this station’s ID,
set the MPIE bit to 1 again, and
clear the RDRF flag to 0.
If the data is this station’s ID,
clear the RDRF flag to 0.
SCI status check and data
reception:
Read SSR and check that the
RDRF flag is set to 1, then read
the data in RDR.
Receive error handling and break
detection:
If a receive error occurs, read the
ORER and FER flags in SSR to
identify the error. After
performing the appropriate error
handling, ensure that the ORER
and FER flags are both cleared
to 0.
Reception cannot be resumed if
either of these flags is set to 1.
In the case of a framing error, a
break can be detected by reading
the RxD pin value.
REJ09B0283-0300

Related parts for HD64F2676VFC33