F39-EU1E Omron, F39-EU1E Datasheet - Page 148

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Characteristics
*1. When two or more Units are connected by logical AND, the operating time and response time are the sum total of the operating times and
*2. Represents the operating time when the safety input turns ON with all other conditions set.
*3. Represents the operating time when the logical AND input turns ON with all other conditions set.
*4. This does not include the operating time or response time of Advanced Units that are connected.
*5. This does not include the operating time or response time of internal relays in the G9SX-EX-@.
*6. For the G9SX-@-RT (with screw terminals) only.
Item
Overvoltage category (IEC/EN 60664-1)
Operating time (OFF to ON state) *1
Response time (ON to OFF state) *1
ON-state residual voltage
OFF-state leakage current
Maximum wiring length of safety input and
logic AND input
Reset input time (Reset button pressing time) 100 ms min.
Accuracy of OFF-delay time *5
Insulation
resistance
Dielectric
strength
Vibration resistance
Shock
resistance
Durability
Ambient operating temperature
Ambient operating humidity
Terminal tightening torque *6
Weight
response times, respectively, of all the Units connected by logical AND.
Between logical AND connection
terminals, and power supply
input terminals and other input
and output terminals connected
together
Between all terminals connected
together and DIN track
Between logical AND connection
terminals, and power supply
input terminals and other input
and output terminals connected
together
Between all terminals connected
together and DIN track
Between different poles of
outputs
Between safety relay outputs
connected together and other
terminals connected together
Destruction
Malfunction
Electrical
Mechanical
http://www.ia.omron.com/
Model
II
50 ms max. (Safety input: ON)
*2
100 ms max. (Logical AND
connection input: ON) *3
15 ms max.
3.0 V max. (safety output, auxiliary output)
0.1 mA max. (safety output, auxiliary output)
100 m max.
(External connection impedance: 100
Within
20 M
500 VAC for 1 min
---
Frequency: 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
300 m/s
100 m/s
---
---
25% to 85%
0.5 N·m
Approx. 200 g
G9SX-AD322-@/ADA222-@
10 to 55 C (with no icing or condensation)
min. (at 100 VDC)
2
2
5% of the set value
50 ms max. (Safety input: ON) 30 ms max. *4
---
---
20 M min. (at 100 VDC)
---
500 VAC for 1 min
---
Approx. 125 g
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
G9SX-BC202-@
max. and 10 nF max.)
II (Safety relay outputs 13 to
43 and 14 to 44: III)
10 ms max. *4
Within
---
100 M min. (at 500 VDC)
---
1,200 VAC for 1 min
2,200 VAC for 1 min
100,000 cycles min.
(rated load, switching
frequency: 1,800 cycles/hour)
5,000,000 cycles min.
(switching frequency: 7,200
cycles/hour)
Approx. 165 g
G9SX-EX-@
5% of the set value
G9SX
9

Related parts for F39-EU1E