F39-EU1E Omron, F39-EU1E Datasheet - Page 584

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Logical AND Connection
Note: See Logical AND Connection Combinations below for details.
*1. The number of G9SX-EX401-@ Expansion Units or G9SX-EX041-T-@ Expansion Units (OFF-delayed Model) not included.
*2. G9SX-EX401-@ Expansion Units and G9SX-EX041-T-@ Expansion Units (OFF-delayed Model) can be mixed.
Logical AND Connection Combinations
1. One logical AND connection output from a G9SX-NS@ Controller
2. Any G9SX-NS@ Controller that receives a logical AND connection
Note: The G9SX-NS@ in the above diagram can be replaced by the
Item
Number of Units connected per logical
AND output
Total number of Units connected by
logical AND *1
Number of Units connected in series
by logical AND
Max. number of Expansion Units
connected *2
Maximum cable length for logical AND
input
can be logical AND connected to up to four Controllers.
input can be logically connected to other Controllers on up to five
layers.
G9SX-NS@
G9SX-NS@
G9SX-NS@
G9SX-NS@
G9SX-NS@
G9SX-NS@
G9SX-AD@ Advanced Unit.
For details on G9SX-AD@ Advanced Units, refer to the
G9SX-series Flexible Safety Unit catalog. (Cat. No. J150).
G9SX-NS@
http://www.ia.omron.com/
G9SX-NS@
Model
G9SX-NS@
4 Units max.
20 Units max.
5 Units max.
100 m max.
G9SX-NS202-@
G9SX-NS@
---
3. The largest possible system configuration contains a total of 20
G9SX-NS@ Controllers, G9SX-AD@ Advanced Units, and
G9SX-BC Basic Units. In this configuration, each Controller or
Advanced Unit can have up to five Expansion Units.
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
Number of Units connected
in series by logical AND: 5
Units max.
G9SX-@
G9SX-NSA222-T03-@
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
or
or
or
or
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
or
or
or
or
or
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
or
or
or
or
or
5 Units max.
D40A/G9SX-NS
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
Total number of Units
connected by logical AND:
20 Units max.
G9SX-EX-@
Number of Units connected
per logical AND output: 4
Units max.
or
or
or
---
---
---
---
G9SX-AD@
G9SX-NS@
G9SX-AD@
G9SX-NS@
or
or
9