F39-EU1E Omron, F39-EU1E Datasheet - Page 23

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Input Modules
L1
Note: For details on the signals and wiring of Two-hand Control
D1
Relay Output Modules
Indicator Display, Lighting Patterns, and Meaning for L1/L2/D1 Modules
The ER1 indicator display indicates errors in Modules in the first set, and the ER2 indicator display indicates errors in Modules in the second set.
Note: Refer to the F3SX User’s Manual for LED lighting patterns on B1 Models.
Terminal
Terminal
Terminal
ER1/ER2 indicator
11/12
23/24
33/34
No.
No.
10
11
12
13
14
15
16
10
11
12
13
14
15
16
No.
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1-time flashing
2-time flashing
Switches, refer to “F3SX-N-L1D1R Auto-reset Circuit Example”
on page 17.
Lit
Not used.
Contact such as Safety Limit Switch or
Safety Door Switch
Contact such as Safety Limit Switch or
Safety Door Switch
Contact such as Safety Limit Switch or
Safety Door Switch
Contact such as Safety Limit Switch or
Safety Door Switch
Not used.
Not used.
2hand-SW S32 NC contact
Not used.
2hand-SW S31 NC contact
2hand-SW S32 NO contact
2hand-SW S32 COMMON
2hand-SW S31 NO contact
2hand-SW S31 COMMON
Test input
Control output 2
Reset input
Control output 1
RS-485 (B)
RS-485 (A)
0 V
+24 V
Auxiliary relay output (N.C.)
Safety relay output (N.O.)
Safety relay output (N.O.)
http://www.ia.omron.com/
Function
Input sync error in input device
Short-circuit or wiring error between inputs
of input device.
Error in input terminal circuit of input
device.
Connection
Connection
Meaning
Two-hand Control Switch
F3SN/F3SJ Safety Light
Curtain or F3SH Multi-beam
Safety Sensor
First set
Second set
The input device contacts are faulty or the
input device wiring is incorrect.
The input device wiring is short-circuited.
Excessive noise is affecting the F3SX.
The input device input circuits are faulty.
L2
B1
Terminal
Terminal
Cause
No.
No.
10
11
12
13
14
15
16
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
Test input
+24 V
0 V
RS-485 (A)
RS-485 (B)
Control output 1
Reset input
Control output 2
Test input
Test input
Control output 2
Reset input
Control output 1
RS-485 (B)
RS-485 (A)
0 V
+24 V
+24 V
0 V
Control output
Test input
+24 V
0 V
Control output
Test input
Test input
Control output
0 V
+24 V
Control output
0 V
+24 V
Check the input device and wiring.
Check the wiring to the input device.
Check the noise environment around the
F3SX.
Replace the F3SX.
Connection
Connection
F3SN/F3SJ Safety Light
Curtain or F3SH Multi-beam
Safety Sensor (first set)
F3SN/F3SJ Safety Light
Curtain or F3SH Multi-beam
Safety Sensor (second set)
E3FS/E3ZS Single-beam
Safety Sensor (first set)
E3FS/E3ZS Single-beam
Safety Sensor (second set)
E3FS/E3ZS Single-beam
Safety Sensor (third set)
E3FS/E3ZS Single-beam
Safety Sensor (fourth set)
Remedy
F3SX