F39-EU1E Omron, F39-EU1E Datasheet - Page 602

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
23. Logical AND connections between Units (Refer to “Functions” on
24. To determine safety distance to hazards, take into account the
25. Start the rest of the system after 5 s or longer has passed since
26. Be sure to ground the A2 terminal of the power supply to help
27. Devices connected to the G9SX-NS may operate unexpectedly.
28. Adhesion of solvent
29. Do not mix AC and DC circuits for contact outputs in a single
Switch and Actuator Operation
Switch and Actuator Mounting Directions
Switch and Actuator Operating Directions
page 17.)
1. To use logical AND connection inputs, enable the logical AND
2. Connect the logical AND connection inputs appropriately to the
3. When configuring the safety system, be sure to consider that
4. Use 2-conductor cabtire cable or shielded cable for logical AND
delay of safety outputs caused by the following time:
1. Response time of safety inputs
2. Response time of D40A Non-contact Door Switch inputs
3. Response time of logical AND connection input
4. Preset OFF-delay time
5. Accuracy of OFF-delay time
applying supply voltage to all G9SX-@ in the system.
prevent malfunctions caused by noise. Also, connect a surge
absorber to each end of the coil on inductive loads to reduce noise
generation. When sharing a power supply with a Light Curtain,
use a DC power supply that will not fail for a momentary power
interruption of 20 ms or less.
When replacing the G9SX-NS, disconnect it from power supply.
Do not allow organic solvents, such as alcohol, thinner,
trichloroethane, or gasoline, to come into contact with the product.
Such solvents make the markings on G9SX-NS illegible and
cause deterioration of parts.
G9SX-EX@-@. When using AC and DC circuits, connect at least
two G9SX-EX@-@ Units and use them respectively as dedicated
DC-circuit and AC-circuit contact outputs.
connection input for the G9SX-NS@ that will receive the inputs.
logical AND connection outputs of the G9SX-@.
the delay of response time caused by logical AND connection
does not degrade the safety functions of the system. (Refer to
“Response Time and Operating Time” on page 10.)
connect ions between Units.
(Refer to “Response Time and Operating Time” on page 10.)
Correct
Switch
http://www.ia.omron.com/
Actuator
Correct
Correct
Switch
Actuator
Incorrect
Safety Category
When used in combination with the G9SX-NS@, the D40A can be
used for the environments corresponding to safety category 3 as
required by EN 954-1. The settings are determined by circuit
examples provided by OMRON, however, and may not be applicable
depending on the operating conditions.
Safety categories are determined for the safety control system as a
whole. You must confirm conformity for the entire system.
To conform with Safety Category 3 (EN954-1):
1. Input two channels for the external inputs (T11-T12, T21-T22).
2. Use switches with direct opening mechanisms for external inputs
3. Connect D40A Switches for Non-contact Door Switch input
4. Input the contactor’s NC signal between T31 and T32 (manual
5. The A2 terminal must be grounded.
Approved Standards
D40A-@/G9SX-NS@/G9SX-NSA@
(T11-T12, T21-T22).
When using limit switches, use at least one switch with direct
opening mechanisms for an input.
terminals (D1, D2, D3, D4).
reset) or between T31 and T33 (auto reset). Refer to “Application
Examples” on page 22.
Approved by TÜV Product Service
EN 50178
EN 1088
IEC/EN 60204-1
EN 954-1 Cat. 3
IEC/EN 61508 SIL3
IEC/EN 60947-5-2
IEC/EN 60947-5-3 PDF-M
Approved by UL
UL 508
CAN/CSA C22.2 No.14
KOSHA certification
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
(EN 954-1)
D40A/G9SX-NS
27