F39-EU1E Omron, F39-EU1E Datasheet - Page 621

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Safety Precautions
Refer to the “Precautions for All Switches” and “Precautions for All Safety Door Switches”.
Serious injury may possibly occur due to breakdown of
safety outputs.
Do not connect loads beyond the rated value to the
safety outputs.
Serious injury may possibly occur due to loss of required
safety functions.
Wire D40B properly so that supply voltages or voltages
for loads do NOT touch the safety inputs accidentally or
unintentionally.
Be sure to turn OFF the power before performing wiring.
Do not touch charged parts (e.g., terminals) while power
is ON. Doing so may result in electric shock.
Do not allow the Actuator to come close to the Switch
with the door open. Doing so may cause machinery to
start operating and may result in injury.
Use stoppers in the way shown below to ensure that the
Switch and Actuator do not make contact when the guard
door is closed.
Guard door
Switch
http://www.ia.omron.com/
!WARNING
!CAUTION
Stopper
2 mm min.
3 mm max. ( Standard Sensor)
4 mm max. (Elongated Sensor)
Actuator
Do not use the product in locations subject to explosive or
flammable gases.
Do not use load currents exceeding the rated value.
Be sure to wire each conductor correctly.
Be sure to confirm correct operation after completing mounting and
adjustment.
Do not drop or attempt to disassemble the product.
Be sure to use the correct combination of Switch and Actuator.
Do not mount the Switch and Actuator on magnetic materials,
otherwise it may affect the operating distance.
Use a power supply of the specified voltage. Do not use power
supplies with large ripples or power supplies that intermittently
generate incorrect voltages.
Capacitors are consumable and require regular maintenance and
inspection.
Do not touch any of the terminals while the power is being supplied.
Doing so may result in electric shock.
Do not attempt to take any Unit apart while the power is being
supplied.
Doing so may result in electric shock.
Do not allow metal fragments or lead wire scraps to fall inside this
product. These may cause electric shock, fire, or malfunction.
Be sure to turn OFF the power before performing wiring. Not doing
so may result in electric shock.
Apply the specified voltage to input terminals. Applying a different
voltage may prevent proper operation and may result in product
damage or burning.
Do not under any circumstances, use the product for loads that
exceed the product's contact ratings, such as the switching
capacity (switching voltage and switching current). Doing so may
not only result in faulty insulation, contact deposition, contact
failure, or other problems affecting product performance, it may
also result in damage or burning.
Do not drop the product or use components that have been
disassembled. Doing so may not only adversely affect
performance characteristics, it may also result in damage.
Ensure that solvents, such as alcohol, thinner, trichloroethane, or
gasoline do not come into contact with the product. Solvents may
cause markings to fade and components to deteriorate.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Precautions for Safe Use