F39-EU1E Omron, F39-EU1E Datasheet - Page 22

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Indicator Display, Lighting Patterns, and Meanings
* This error does not occur in F3SX Safety Controllers configured without a Relay Output Module.
Continuously flashing
1-time flashing
2-time flashing
3-time flashing
4-time flashing
5-time flashing
6-time flashing
ER indicator
Lit
http://www.ia.omron.com/
Emergency stop
switch input sync error
Short-circuit/wiring
error between
emergency stop switch
inputs
Emergency stop
switch input terminal
circuit error
Reset input terminal
error
External indicator
output terminal error
(F3SX-N)
DC solid-state safety
output terminal error
(F3SX-E)
Relay output terminal
error *
Feedback input
terminal error
Noise or F3SX
malfunction
Meaning
Emergency stop switch contact is faulty or
emergency stop switch wiring is incorrect.
The wiring to the emergency stop switch has
short-circuited.
The emergency stop switch input terminal is
faulty.
Excessive noise is affecting the F3SX.
The wiring to the reset input terminal is incorrect. Check the wiring to the reset input terminal.
The wiring to the reset input terminal is broken or
short-circuited.
The reset input terminal circuit is faulty.
The external indicator output circuit is faulty.
The wiring to the external indicator output circuit
is incorrect
An error has occurred in the external indicator
output circuit.
The load (external device) is faulty.
The wiring to the load (external device) is
incorrect.
An error has occurred in the DC solid-state safety
output circuit.
The relay output is faulty.
Excessive noise is affecting the F3SX.
The wiring to the contactor or other external
device is incorrect.
The contactor or other external device is faulty.
Excessive noise is affecting the F3SX.
The F3SX’s internal circuits are faulty.
Cause
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
Check the wiring to the emergency stop switch.
Check the emergency stop switch and wiring.
Replace the F3SX.
Check the noise conditions around the F3SX.
Check the wiring to the reset input terminal.
Replace the F3SX.
Replace the external indicator.
Check the wiring to the external indicator.
Replace the F3SX.
Replace the load (external device).
Check the wiring to the load (external device).
Replace the F3SX.
Replace the F3SX.
Check the noise conditions around the F3SX.
Check the wiring to the contactor or other
external devices.
Replace the contactor or other external device.
Check the noise conditions around the F3SX.
Replace the F3SX.
Remedy
F3SX