F39-EU1E Omron, F39-EU1E Datasheet - Page 863

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Using the Safety Light Curtain to initiate a machine cycle after an
object is removed from the sensing area is called Presence Sensing
Device Initiation (PSDI). Use of PSDI places additional requirements
on the guarding and safety controls. It can restrict advanced Safety
Light Curtain features such as floating blanking and fixed blanking.
Details on PSDI can be found in ANSI RIA 15.06-1999, OSHA
1910.217(h), and ANSI B11.2-1995 (R2005).
For wiring
For PNP output, connect the load between the output and 0 V
line. Connecting the load between the output and +24 V line
results in a dangerous condition because the operation mode is
reversed to “ON when light is interrupted.”
Do not interconnect an output line with a +24-V line. Otherwise,
the output is always ON, creating a dangerous situation. Also, 0
V of the power supply must be grounded so that output does not
turn ON due to grounding of the output line.
Configure the system by using the optimal number of control
outputs that satisfy the requirements of the necessary safety
category.
Do not connect the lines of the MS/MSF4800 to a DC power
supply higher than 24 V +20%. Also, do not connect to an AC
power supply. Otherwise, it may result in electric shock.
Programming and Diagnostics Module
The MS/MSF4800-series Safety Light Curtains require the use of a
Programming and Diagnostics Module (PDM) to program the
operating parameters of the Light Curtain. In addition to Safety Light
Curtain configuration, this Module also serves as a diagnostics
device, allowing the user to retrieve fault information.
Note: The light curtain does not require the PDM to operate. The
• Displays programming and diagnostics information on a multi-line
• Supports English and Japanese languages. To switch between
• The housing is rated IP65, allowing permanent mounting near the
Up/Down Scroll Buttons
Sensor Restart of Machine Cycle Operation (PSDI)
LCD display.
English and Japanese, continue to press the right Forward/
Backward Scroll Button more than ten times at the log-in screen
that appears after the PDM is connected to the MS/MSF4800.
Safety Light Curtain.
Forward/Backward
factory default settings allow for basic guarding operation.
Scroll Buttons
http://www.ia.omron.com/
WARNING
In the interest of product improvement, specifications are subject to change without notice.
Enter Button
For the MS/MSF4800 to comply with IEC 61496-1 and UL 508, the
DC power supply unit must satisfy all of the following
conditions:
Double or enhanced insulation from hazardous voltage must be
applied to all input and output lines. Failure to do so may result
in electric shock.
The cable extension length must be no greater than the specified
length. Otherwise, the safety functions may fail to work properly,
resulting in danger.
PDM Navigation Buttons
Note: For information on the operating method, refer to the Mini Safe
• Must be within rated power voltage (24 VDC ±20%).
• Must have tolerance against the total rated current of devices
• Must comply with EMC directives (industrial environment).
• Double or enhanced insulation must be applied between the
• Automatic recovery must be possible for overcurrent
• Output holding time must be 20 ms or longer.
• Must satisfy output characteristic requirements for class 2
• Must comply with the EMC, laws, and regulations of the
Forward/
Backward
Scroll But-
tons
Up/Down
Scroll But-
tons
Enter But-
ton
if it is connected to multiple devices.
primary and secondary circuits.
protection.
circuit or limited voltage current circuit defined by UL508.
country or region where the MS/MSF4800 is used. (For
example, in the EU, the power supply must comply with the
EMC Low Voltage Directive.)
Name
4800 Series Safety Light Curtains Installation and Operating
Manual.
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
Shape
Scroll forward and backward to
review the previous and next
menu, or to move within the
same screen.
Scroll up and down to review the
selection of the current menu.
When pressed the selected func-
tion will be accessed.
Description
MS4800
33