F39-EU1E Omron, F39-EU1E Datasheet - Page 42

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Applicable Safety Category (EN954-1)
All G9S-series Relays fall under Safety Category 4 of EN954-1
except the G9S-321-T. The G9S-321-T has an OFF-delay output
block falling under Safety Category 3.
The above is provided according to circuit examples presented by
OMRON. Therefore, the above may not apply to all operating
environments.
The applicable safety category is determined from the whole safety
control system. Make sure that the whole safety control system meets
EN954-1 requirements.
Wire the G9S-2002 for auto-reset. If either one of them is
connected to a manual reset switch, EN954-1 requirements will not
apply.
Safety Category 4 of EN954-1
Certified Standards
The G9S-301, G9S-501, G9S-321-T and G9S-2002 conform to the
following standards.
Wire the G9S-2002 for auto-reset. If it is connected to a manual
reset switch, EN954-1 requirements will not apply.
Apply 2-channel external input to the T11 and T12 terminals and
T21 and T22 terminals through switches each incorporating a
force-separation mechanism. If limit switches are used, make sure
that at least one of them incorporates a force-separation
mechanism.
Refer to Application Examples and input a signal for the
normally-closed contact of the contactor (i.e., input to X1 of the
G9S-301, X2 of the G9S-501, or X2 of the G9S-321-T).
Be sure to ground the PE terminal. If the relay is operating with DC,
the power supply may be grounded instead.
EN standards, certified by BIA:
EN954-1
EN60204-1
Conformance to EMC (Electromagnetic Compatibility), certified by
TÜV Product Service:
EMI (Emission): EN55011 Group 1 Class A
EMS (Immunity): EN61000-6-2
UL standards: UL508 (Industrial Control Equipment)
CSA standards: CSA C22.2 No. 14 (Industrial Control Equipment)
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
G9S
10

Related parts for F39-EU1E