F39-EU1E Omron, F39-EU1E Datasheet - Page 397

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Contacts
* In the above table, cos = 0.3 for AC-15 inductive loads and L/R = 96 ms for DC-13 inductive loads.
Characteristics of Sockets
Note: Use the P7S-14F-END in the ambient humidity range of 35 to 85%.
* Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC.
Characteristics
Note: The above values are initial values.
*1. Measurement conditions: 5 VDC, 10 mA, voltage drop method.
*2. Measurement conditions: Rated voltage operation
*3. The insulation resistance was measured with a 500-VDC megohmmeter at the same locations as the dielectric strength was measured.
*4. When using a P7S Socket, the dielectric strength between coil and contacts and between different poles is 2,000 VAC, 50/60 Hz for 1 min.
*5. The coil refers to terminals 0-1, pole 1 refers to terminals 13 14, pole 2 refers to terminals 23 24, pole 3 refers to terminals 33 34, pole 4 refers
*6. The durability is for an ambient temperature of 15 to 35 C and an ambient humidity of 25% to 75%.
*7. The failure rate is based on an operating frequency of 60 operations/min.
Item
Rated load
Rated carry current
Maximum switching voltage
Maximum switching current
Contact resistance *1
Operating time *2
Release time *2
Maximum operating
frequency
Insulation resistance *3
Dielectric strength *4 *5
Vibration
resistance
Shock resistance
Durability *6
Failure rate (P level)
(reference value *7)
Ambient operating temperature
Ambient operating humidity
Weight
Ambient operating temperature: 23 C
Contact bounce time is not included.
to terminals 41 42 or 43 44, pole 5 refers to terminals 51 52, and pole 6 refers to terminals 61 62.
P7S-14@
Model
http://www.ia.omron.com/
Mechanical
Rated load
Destruction 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude)
Destruction 1,000 m/s
Malfunction 100 m/s
Mechanical
Electrical
Continuous current
100 m max.
50 ms max.
50 ms max.
18,000 operations/h
1,800 operations/h
100 M min.
Between coil and contacts:
Between coil and pole 3 or coil and pole 4: 4,000 VAC, 50/60 Hz for 1 min
Other than the above:2,500 VAC, 50/60 Hz for 1 min
Between different poles:
Between pole 1, 3, or 5 and pole 2, 4, or 6: 4,000 VAC, 50/60 Hz for 1 min
Other than the above:2,500 VAC, 50/60 Hz for 1 min
Between contacts of same polarity:1,500 VAC, 50/60 Hz for 1 min
10,000,000 operations min. (at approx. 18,000 operations/h)
100,000 operations min. (at the rated load and approx. 1,800 operations/h)
5 VDC, 1 mA
–25 to 70 C (with no icing or condensation)
5% to 85%
Approx. 65 g
NO contact
NC contact
NO contact
NC contact
NO contact
NC contact
10 A
2
2
Load
2000 VAC for 1 min. between terminals
10 A at 250 VAC
10 A at 30 VDC
6 A at 250 VAC
Resistive load
6 A at 30 VDC
Dielectric strength
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
250 VAC, 30 VDC
10 A
10 A
6 A
6 A
AC-15: 5 A at 240 VAC
AC-15: 3 A at 240 VAC
DC-13: 2 A at 24 VDC
DC-13: 2 A at 24 VDC
Inductive load *
Insulation resistance
1000 M
G7S-@-E
min. *
2