F39-EU1E Omron, F39-EU1E Datasheet - Page 2

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Safety Input Specifications
(Common with the DST1 Series)
Safety Output Specifications
(Semiconductor output)
(Common with the DST1-MD16SL-1/XD0808SL-1)
Test Output Specifications
(Common with the DST1 Series)
Internal Circuit Configuration
DST1-ID12SL-1
Input type
ON voltage
OFF voltage
OFF current
Input current
Output type
Rated output current 0.5 A max./output
ON residual voltage
Leakage current
Output type
Rated output current 0.7 A max./output
ON residual voltage
Leakage current
Terminal
1, 2
11, 12
35 to 40
3 to 10
21 to 24
13 to 20
25 to 30
31 to 34
No.
V
G
G
IN0 to IN11 Safety input terminal
T0 to T3
Name
http://www.ia.omron.com/
Power supply terminal (24 VDC)
for input device and test output
Common terminal
(Terminal Nos. 11, 12 and 35 to
40 are internally connected.)
Test output terminal
Sinking inputs (PNP)
11 VDC min.
5 VDC max.
1 mA max.
6 mA
Sourcing outputs (PNP)
1.2 V max.
0.1 mA max.
Sourcing outputs (PNP)
1.2 V max.
0.1 mA max.
CAN H
DRAIN
CAN L
V+
V−
Function
DC-DC Converter
(Non-insulated)
11
1
G
V
Input Power
Supply Circuit
12
2
V
G
13
3
IN0
T0
14
4
IN1
T1
15
5
IN2
T0
16
6
IN3
T1
Safety Output Specifications
(Relay Output)
(DST1-MRD08SL-1)
* This value is equivalent to 300 operations/minute.
DeviceNet Safety Communications
DeviceNet Slave Communications
(Common with the DST1 Series)
Applicable relays
Failure rate P level *
(Reference value)
Rated load
(resistive)
Durability
Safety Slave
communications
Standard Slave
communications
17
7
IN4
T0
Safety Input Circuit
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
18
(Sink input)
8
IN5
T1
Mechanical
19
Electrical
9
IN6
T0
10
20
IN7
T1
Internal Circuits
21
31
Max. 4 connections
(Max. 2 connections for the DST1-XD0808SL-1)
Max. 2 connections
IN8
T0
G7SA-2A2B, EN50205 Class A
5 VDC, 1 mA
2 A at 240 VAC, 2 A at 30 VDC
5,000,000 operations min.
(at 7,200 operations/h)
100,000 operations min.
(at 1,800 operations/h with a resistive load)
22
32
IN9
T1
23
33
IN10
T0
24
34
IN11
T1
25
35
T2
G
26
36
DST1 Series
T2
G
Test Output Circuit
(Source output)
27
37
T2
G
28
38
T3
G
29
39
T3
G
30
40
T3
G
2

Related parts for F39-EU1E