F39-EU1E Omron, F39-EU1E Datasheet - Page 21

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Connections
Terminal Arrangement
Main Modules
*1. If the emergency stop switch is not necessary, directly connect terminal T11 to T12, and terminal T21 to T22.
*2. The Function Setup Software for the F3SX (F3SX-CD100-E, sold separately) can be used to change function settings for the auxiliary
*3. When the start command input (SSC) is not necessary, directly connect the SSC terminal to the 24 VDC input terminal (A1 terminal).
*4. When an external indicator is not necessary, connect resistance (1/4 W, 4.7 k ) between the terminals EL1 and EL2.
Item
Power supply inputs
Emergency stop inputs *1
Feedback input
Auxiliary solid-state
outputs *2
Auxiliary input *3
External indicator outputs *4
DC solid-state safety
outputs
RS-232C port
Reset inputs
solid-state output terminals (AS1, AS2, and AS3), and the external indicator output. For details refer to the Help menu in the F3SX-CD100-E.
A1 T11 T12 T21 T22
A2 SSC AS3 AS2 AS1
http://www.ia.omron.com/
Main Module
Control circuits
24 VDC
SS1/
Terminal
Y1
EL1
COM
SSC
AS1
AS2
AS3
SS1
SS2
T11
T12
T21
T22
EL1
EL2
FB
A1
A2
Y1
Y2
Y3
SS2/
Y2
EL2 FB
No.
Y3
24-VDC input
GND (0 V) input
Emergency Stop Switch inputs
Reset inputs: Auto/manual reset selection, system reset
Feedback time monitor (500 ms max.)
Safety output monitor (standard setting: Outputs synchronously with the safety output)
Information trigger
(Standard setting: Outputs error information, information
on excessive output switching, and information on
excessive ON time)
Standby output
(Standard setting: Outputs after power is turned ON, the F3SX has been initialization, and I/O can be normally
controlled.)
Start command input (soft-start circuit)
Indicator input with diagnostic functions (+: sourcing)
Indicator input with diagnostic functions ( : sinking)
RS-232C port for connecting communications cable
1
9 10 11 12
2
3
4
13
5
14
6
15 16
7
F3SX-N
8
---
---
1
9 10 11 12
2
Input Modules
3
4
13
5
14
6
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
15 16
7
8
Function
1
9 10 11 12
Ready output
(Standard setting: Outputs when safety inputs are all ON.)
DC solid-state safety output 1
DC solid-state safety output 2
2
3
4
13
5
14
6
15 16
7
8
F3SX-E
Relay Output Module
K1
K2
---
---
11
12
23
24
33
34
F3SX
13

Related parts for F39-EU1E