F39-EU1E Omron, F39-EU1E Datasheet - Page 725

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Example Setting
When an F3SJ-A@14 is being used with an interrupting object that is
20 mm in diameter, set three light beams as floating light beams. With
this setting, the F3SJ's safety output will not turn OFF even if there is
an interrupting object up to 22-mm wide in the floating blanking area.
Effective Range vs. Number of Floating Light Beams
F3SJ-A@14 Series
F3SJ-A@20 Series
F3SJ-A@30 Series
F3SJ-A@55 series
With 2 floating light beams
With 3 floating light beams
With 4 floating light beams
With 2 floating light beams
With 3 floating light beams
With 4 floating light beams
With 2 floating light beams
With 3 floating light beams
With 4 floating light beams
With 2 floating light beams
With 3 floating light beams
With 4 floating light beams
With 1 floating light beam
With 1 floating light beam
With 1 floating light beam
With 1 floating light beam
0
0
0
0
http://www.ia.omron.com/
4
10
10
20
40
Permitted Floating Range
Permitted Floating Range
Permitted Floating Range
Permitted Floating Range
Size of Interrupting Object (mm)
20
Size of Interrupting Object (mm)
Size of Interrupting Object (mm)
10
45
13
20
Size of Interrupting Object (mm)
Example Setting Size
80
25
40
45
95
20
30
22
120
60
40
40
70
145
Settable Range
30
Settable Range
Settable Range
Settable Range
31
160
80
50
55
95
195
200
100
40
60
Floating Blanking Mode
The floating blanking function has two operation modes.
1. Continuous Light Beam Mode
2. Discontinuous Light Beam Mode
The safety output will not go OFF if the interrupting object is smaller
than the set size, although the safety output will go OFF if objects
pass through several areas in the detection area.
The floating blanking monitor function can be set in this mode.
Refer to the User's Manual for details.
A light blockage is detected when the number of light beams
blocked in the area is equal to or greater than the preset number of
light beams.
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
F3SJ Ver.2
71