F39-EU1E Omron, F39-EU1E Datasheet - Page 508

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Connections
Internal Circuit Diagram
Indicator
Solenoid
E1 (+)
E2 (−)
O1 (+)
O2 (−)
24 VDC
24 VDC
D
http://www.ia.omron.com/
Z
D
R
LED
Circuit Connection Example
(Examples for the D4JL-@NF@-@)
O1
O2
E1
(+)
E2
(−)
(+)
(−)
Terminals 11-42 and terminals 21-52 are connected internally and
so connect terminals 12-41 and 22-51 for safety-circuit input
(GS-ET-19).
Direct opening contacts used as safety-circuit input are indicated
with the
Terminals 11-12 and terminals 21-22 are direct opening contacts.
Do not connect the indicator directly to direct opening contacts. If
indicator is connected in parallel with direct opening contacts, a
short-circuit current may flow in the event that the indicator is
damaged, causing equipment to malfunction.
Do not switch standard loads for more than 2 circuits at the same
time. Otherwise, the level of insulation may decrease.
The solenoid terminals have polarity (E1: + and E2: ). Confirm the
polarity before wiring.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
LED
Lock Monitor Switch
41
51
63
mark.
42
52
64
Door Open/
closed
Detection
Switch
11
21
33
12
22
34
To safety circuit
To safety circuit
To control circuit
To control circuit
D4JL
8