F39-EU1E Omron, F39-EU1E Datasheet - Page 844

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Example When Connected to the G9SB-301-D Controller (Category 4)
MS/MSF4800 Settings
G9SB-301-D Settings
• Auto start mode
• External device monitoring not used
• Test input used.
• Manual reset mode
• Feedback loop used
• Emergency stop switch used
(Use the PDM to enable the test input.)
Emergency stop switch (S4)
G9SB-301-D
Interlock reset switch (S3)
http://www.ia.omron.com/
External test switch (S1)
E1
KM1, KM2 NO contacts
KM1, KM2 NC contacts
+24 VDC
K1, K2 NO contacts
Ground
K1, K2 NC contacts
0 V
Light interrupted
Control output
Light incident
PLC input 1
PLC input 2
PLC output
A1
*
A2
3
Transmitter
T21
Depends on the output operation
mode of the auxiliary output
T11
T12
K1
K1
*
2
a K2
T22
K2
a
K2
T31
Control
circuit
T32
K1
KM1
KM2
*
Receiver
1
K1
K2
KM1
13
14
*1. For the MS/MS4800B, use NC contacts for the start input switch.
*2. Fuse (provided by the customer).
*3. The test input is disabled with the default setting. To use the test input,
23
24
12
11
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
S1: External test switch
S2: Start input
S3 : Interlock reset switch
S4: Emergency stop switch (A165E, A22E, etc.)
KM1, KM2: Magnetic contactors
KM3: Solid-state contactor (G3J)
M: 3-phase motor
E1: 24-VDC power supply
PLC: Programmable Controller
For the MS/MS4800A, refer to Start Input Methods (MS/MSF4800A
Only) on page 19.
connect the PDM to the Receiver and enable the test input, and use
NC contacts for the test input.
KM2
33
34
22
21
(Used for monitoring. This is not a part of a safety system.)
41
42
S4
IN1
PLC
IN2
OUT
KM3
KM1
KM2
M
MS4800
14

Related parts for F39-EU1E