F39-EU1E Omron, F39-EU1E Datasheet - Page 626

F3S-B OPTIONAL PROGRAMMING KIT

F39-EU1E

Manufacturer Part Number
F39-EU1E
Description
F3S-B OPTIONAL PROGRAMMING KIT
Manufacturer
Omron
Datasheet

Specifications of F39-EU1E

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Light Curtain Type
Safety
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Precautions for All Switches
Refer to the Safety Precautions section for each Switch for specific precautions applicable to each Switch.
Wiring
Pay the utmost attention so that each terminal is wired correctly.
If the terminal is wired incorrectly, the Switch will not function.
Furthermore, not only will the Switch have a negative influence on the
external circuit, the Switch itself may become damaged or burnt.
If the Switch is to be used as a switch in an emergency stop circuit
or in a safety circuit for preventing accidents resulting in injuries or
deaths, use a Switch with a direct opening mechanism, use the NC
contacts with a forced release mechanism, and set the Switch so
that it will operate in direct opening mode.
For safety, install the Switch using one-way rotational screws or
other similar means to prevent it from easily being removed.
Protect the Switch with an appropriate cover and post a warning
sign near the Switch to ensure safety.
Do not perform wiring while power is being supplied. Wiring while
the power is being supplied may result in electric shock.
Keep the electrical load below the rated value.
Be sure to evaluate the Switch under actual working conditions
after installation.
Do not touch the charged Switch terminals while the Switch has
carry current, otherwise an electric shock may be received.
If the Switch has a ground terminal, be sure to connect the ground
terminal to a ground wire.
The durability of the Switch greatly varies with switching
conditions. Before using the Switch, be sure to test the Switch
under actual conditions. Make sure that the number of switching
operations is within the permissible range.
If a deteriorated Switch is used continuously, insulation failures,
contact welding, contact failures, Switch damage, or Switch
burnout may result.
Maintain an appropriate insulation distance between wires
connected to the Switch.
Some types of load have a great difference between normal
current and inrush current. Make sure that the inrush current is
within the permissible value. The greater the inrush current in the
closed circuit is, the greater the contact abrasion or shift will be.
Consequently, contact welding, contact separation failures, or
insulation failures may result. Furthermore, the Switch may
become broken or damaged.
The user must not attempt to repair or maintain the Switch and
must contact the machine manufacturer for any repairs or
maintenance.
Do not attempt to disassemble or modify the Switch. Doing so may
cause the Switch to malfunction.
Do not drop the Switch. Doing so may result in the Switch not
performing to its full capability.
(A)
I
Precautions for Safe Use
http://www.ia.omron.com/
i (Inrush current)
io (Constant
current)
t
Mounting
Do not modify the Actuator, otherwise the operating characteristics
and performance of the Actuator will change.
Do not enlarge the mounting holes of the Switch or modify the
Switch, otherwise insulation failures, housing damage, or human
accidents may result.
Do not apply oil, grease, or other lubricants to the moving parts of
the Actuator, otherwise the Actuator may not operate correctly.
Furthermore, ingress of oil, grease, or other lubricants inside the
Switch may reduce sliding characteristic or cause failures in the
Switch.
Mount the Switch and secure it with the specified screws tightened
to the specified torque along with flat and spring washers.
Be sure to wire the Switch so that the conduit opening is free of
metal powder or any other impurities.
If glue or bonding agent is applied, make sure that it does not
adhere to the movable parts or enter the Switch, otherwise the
Switch may not work correctly or cause contact failure. Some types
of glue or bonding agent may generate a gas that may have a
negative influence on the Switch. Pay the utmost attention when
selecting the glue or locking agent.
Some models allow changes in the head direction. When changing
the head of such a model, make sure that the head is free of any
foreign substance. Tighten each screw of the head to the rated
torque.
Be sure to take measures so that no foreign material, oil, or water
will enter the Switch through the conduit opening. Be sure to attach
a connector suitable for the cable thickness and tighten the
connector securely to the rated torque.
Do not impose shock or vibration on the Actuator while it is fully
pressed. Otherwise, the Actuator will partially abrade and an
actuation failure may result.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
C-3