PNX1702EH/G,557 NXP Semiconductors, PNX1702EH/G,557 Datasheet - Page 764

no-image

PNX1702EH/G,557

Manufacturer Part Number
PNX1702EH/G,557
Description
IC MEDIA PROC 500MHZ 456-BGA
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PNX1702EH/G,557

Applications
Multimedia
Core Processor
TriMedia
Controller Series
Nexperia
Ram Size
208K x 8
Interface
I²C, 2-Wire Serial
Number Of I /o
61
Voltage - Supply
1.33 V ~ 1.47 V
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
456-HBGA
Operating Temperature (min)
0C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Program Memory Type
-
Lead Free Status / Rohs Status
Compliant
Other names
935281647557
PNX1702EH/G
PNX1702EH/G
Philips Semiconductors
Volume 1 of 1
PNX17XX_SER_1
Preliminary data sheet
2.1.2 Serial Clock Generator
2.1.3 Bit Counter
2.1.4 Control Register
2.1.5 Status Decoder and Register
2.1.6 Input Filter
2.1.7 Address Register and Comparator
A slave may stretch the space duration to slow down the bus master. The space
duration may also be stretched for handshaking purposes. This can be done after
each bit or after a complete byte transfer. The IIC module will stretch the SCL space
duration after a byte has been transmitted or received and the acknowledge bit has
been transferred. This block also controls all of the signals for serial byte handling. It
provides the shift pulses for DAT, enables the comparator, generates and detects
START and STOP conditions, receives and transmits acknowledge bits, controls the
master and slave modes, contains interrupt request logic and monitors the I
status.
This programmable clock pulse generator provides the SCL clock pulses when the
IIC module is in master transmitter or master receiver mode. It is switched off when
the IIC module is in a slave mode. The output frequency is dependent on the CR bits
in the control register. The output clock pulses have a 50% duty cycle unless the
clock generator is synchronized with other SCL clock sources, as described above.
The bit counter tracks the number of bits that have been received during the byte
transfer. The output from this counter is used to trigger events, such as address
recognition and acknowledge generation, which occur at specific points during the
byte transfer.
This register is used by the micro controller to control the generation of START and
STOP conditions, enable the interface, control the generation of ACKs, and to select
the clock frequency.
There are 26 possible bus states if all four modes of the IIC module are used. The
status decoder takes all of the internal status bits and compresses them into a 5-bit
code. This code is unique for each I
processing the various service routines. Each service routine processes a particular
bus status. The 5-bit status code is stored in bits 7-3 of the status register. Bits 2-0
and 31-8 of the status register are always zero.
Input signals SDA and SCL from IO pad cells are synchronized with the internal
clock. Spikes shorter than three clock periods are filtered out.
This SFR may be loaded with the 7-bit slave address to which IIC module will
respond when programmed as a slave. The least significant bit is used to enable the
general call address recognition. The comparator compares the received 7-bit slave
address with its own slave address. It also compares the first received 8-bit byte with
the general call address. If an equality is found, the appropriate status bits are set
and an interrupt is requested.
Rev. 1 — 17 March 2006
2
C bus status. The 5-bit code may be used for
© Koninklijke Philips Electronics N.V. 2006. All rights reserved.
PNX17xx Series
Chapter 25: I
2
C Interface
2
C bus
25-3

Related parts for PNX1702EH/G,557