SAM3U2C Atmel Corporation, SAM3U2C Datasheet - Page 1009

no-image

SAM3U2C

Manufacturer Part Number
SAM3U2C
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3U2C

Flash (kbytes)
128 Kbytes
Pin Count
100
Max. Operating Frequency
96 MHz
Cpu
Cortex-M3
# Of Touch Channels
28
Hardware Qtouch Acquisition
No
Max I/o Pins
57
Ext Interrupts
57
Usb Transceiver
1
Quadrature Decoder Channels
1
Usb Speed
Hi-Speed
Usb Interface
Device
Spi
4
Twi (i2c)
1
Uart
4
Ssc
1
Sd / Emmc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
12
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
36
Self Program Memory
YES
External Bus Interface
1
Dram Memory
No
Nand Interface
Yes
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
Yes / No
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
• ERR_OVFLW: Overflow Error
This bit is set by hardware when a new too-long packet is received.
Example: If the user programs an endpoint 64 bytes wide and the host sends 128 bytes in an OUT transfer, then the Over-
flow Error bit is set.
This bit is updated at the same time as the BYTE_COUNT field.
This bit is reset by UDPHS_EPTRST register EPT_x (reset endpoint) and by UDPHS_EPTCTLDISx (disable endpoint).
• RX_BK_RDY/KILL_BANK: Received OUT Data/KILL Bank
This bit is set by hardware after a new packet has been stored in the endpoint FIFO.
This bit is cleared by the device firmware after reading the OUT data from the endpoint.
For multi-bank endpoints, this bit may remain active even when cleared by the device firmware, this if an other packet has
been received meanwhile.
Hardware assertion of this bit may generate an interrupt if enabled by the UDPHS_EPTCTLx register RX_BK_RDY bit.
This bit is reset by UDPHS_EPTRST register EPT_x (reset endpoint) and by UDPHS_EPTCTLDISx (disable endpoint).
Note:
• TX_COMPLT: Transmitted IN Data Complete
This bit is set by hardware after an IN packet has been transmitted for isochronous endpoints and after it has been
accepted (ACK’ed) by the host for Control, Bulk and Interrupt endpoints.
This bit is reset by UDPHS_EPTRST register EPT_x (reset endpoint), and by UDPHS_EPTCTLDISx (disable endpoint).
• TX_PK_RDY/ERR_TRANS: TX Packet Ready/Transaction Error
This bit is cleared by hardware, as soon as the packet has been sent for isochronous endpoints, or after the host has
acknowledged the packet for Control, Bulk and Interrupt endpoints.
For Multi-bank endpoints, this bit may remain clear even after software is set if another bank is available to transmit.
Hardware clear of this bit may generate an interrupt if enabled by the UDPHS_EPTCTLx register TX_PK_RDY bit.
This bit is reset by UDPHS_EPTRST register EPT_x (reset endpoint), and by UDPHS_EPTCTLDISx (disable endpoint).
This bit is set by hardware when a transaction error occurs inside one microframe.
If one toggle sequencing problem occurs among the n-transactions (n = 1, 2 or 3) inside a microframe, then this bit is still
set as long as the current bank contains one “bad” n-transaction. (see
Bank/Control Direction” on page
is reset.
6430E–ATARM–29-Aug-11
6430E–ATARM–29-Aug-11
– Received OUT Data: (For OUT endpoint or Control endpoint)
– KILL Bank: (For IN endpoint)
– the bank is really cleared or the bank is sent, BUSY_BANK_STA is decremented.
– the bank is not cleared but sent on the IN transfer, TX_COMPLT
– the bank is not cleared because it was empty. The user should wait that this bit is cleared before trying to clear
– TX Packet Ready:
– Transaction Error: (For high bandwidth isochronous OUT endpoints) (Read-Only)
another packet.
“Kill a packet” may be refused if at the same time, an IN token is coming and the current packet is sent on the UDPHS line. In
this case, the TX_COMPLT bit is set. Take notice however, that if at least two banks are ready to be sent, there is no problem to
kill a packet even if an IN token is coming. In fact, in that case, the current bank is sent (IN transfer) and the last bank is killed.
1011) As soon as the current bank is relative to a new “good” n-transactions, then this bit
“CURRENT_BANK/CONTROL_DIR: Current
SAM3U Series