HD64F3437STF16V Renesas Electronics America, HD64F3437STF16V Datasheet - Page 300

MCU 3/5V 60K PB-FREE 100-TQFP

HD64F3437STF16V

Manufacturer Part Number
HD64F3437STF16V
Description
MCU 3/5V 60K PB-FREE 100-TQFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300r
Datasheet

Specifications of HD64F3437STF16V

Core Processor
H8/300
Core Size
8-Bit
Speed
16MHz
Connectivity
Host Interface, I²C, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
74
Program Memory Size
60KB (60K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3437STF16V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3437STF16V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
In receiving, the SCI operates as follows.
1. The SCI monitors the receive data line and synchronizes internally when it detects a start bit.
2. Receive data is shifted into RSR in order from LSB to MSB.
3. The parity bit and stop bit are received.
Note: When a receive error flag is set, further receiving is disabled. The RDRF bit is not set to 1.
4. After setting RDRF to 1, if the RIE bit (receive-end interrupt enable) is set to 1 in SCR, the
Table 12.10 Receive Error Conditions and SCI Operation
Receive Error
Overrun error
Framing error
Parity error
268
After receiving these bits, the SCI makes the following checks:
a. Parity check: The number of 1s in the receive data must match the even or odd parity
b. Stop bit check: The stop bit value must be 1. If there are two stop bits, only the first stop bit
c. Status check: RDRF must be 0 so that receive data can be loaded from RSR into RDR.
If these checks all pass, the SCI sets RDRF to 1 and stores the received data in RDR. If one of
the checks fails (receive error), the SCI operates as indicated in table 12.10.
SCI requests an RXI (receive-end) interrupt. If one of the error flags (ORER, PER, or FER) is
set to 1 and the RIE bit in SCR is also set to 1, the SCI requests an ERI (receive-error)
interrupt.
setting of the O/E bit in SMR.
is checked.
Be sure to clear the error flags.
Abbreviation
ORER
FER
PER
Condition
Receiving of next data ends
while RDRF is still set to 1
in SSR
Stop bit is 0
Parity of receive data differs
from even/odd parity setting
in SMR
Data Transfer
Receive data not loaded from
RSR into RDR
Receive data loaded from
RSR into RDR
Receive data loaded from
RSR into RDR