EP1S20F780I6N Altera, EP1S20F780I6N Datasheet - Page 540

IC STRATIX FPGA 20K LE 780-FBGA

EP1S20F780I6N

Manufacturer Part Number
EP1S20F780I6N
Description
IC STRATIX FPGA 20K LE 780-FBGA
Manufacturer
Altera
Series
Stratix®r
Datasheets

Specifications of EP1S20F780I6N

Number Of Logic Elements/cells
18460
Number Of Labs/clbs
1846
Total Ram Bits
1669248
Number Of I /o
586
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
780-FBGA
Family Name
Stratix
Number Of Logic Blocks/elements
18460
# I/os (max)
586
Frequency (max)
450.05MHz
Process Technology
0.13um (CMOS)
Operating Supply Voltage (typ)
1.5V
Logic Cells
18460
Ram Bits
1669248
Operating Supply Voltage (min)
1.425V
Operating Supply Voltage (max)
1.575V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
780
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S20F780I6N
Manufacturer:
ALTERA
Quantity:
3 000
Part Number:
EP1S20F780I6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S20F780I6N
Manufacturer:
ALTERA
0
Software Support
5–68
Stratix Device Handbook, Volume 2
Stratix devices, you can align the input data with respect to the
tx_inclock port and align the output data with respect to the
tx_outclock port. The MegaWizard Plug-In Manager uses the
alignment of input and output data to automatically calculate the phase
for the fast PLL outputs. Both of these parameters default to
EDGE_ALIGNED, and other values are CENTER_ALIGNED, 45_DEGREES,
135_DEGREES, 180_DEGREES, 225_DEGREES, 270_DEGREES, and
315_DEGREES. CENTER_ALIGNED is the same as 180 degrees aligned
and is required for the HyperTransport technology I/O standard.
Clock Frequency & Clock Period
The fields in the Specify the input clock rate by box specify either the
frequency or the period of the input clock going into the fast PLL.
However, you cannot specify both. If your design uses the same input
clock to feed a transmitter and a receiver module simultaneously, the
Quartus II software can merge the fast PLLs for both the transmitter and
receiver when the Use common PLLs for Tx & Rx option is turned on.
Page 4 of the altlvds_tx MegaWizard Plug-In Manager
This section describes the parameters found on page 4 of the
altlvds_tx MegaWizard Plug-In Manager (see
Figure
Altera Corporation
5–43).
July 2005

Related parts for EP1S20F780I6N