h8s-2635 Renesas Electronics Corporation., h8s-2635 Datasheet - Page 161

no-image

h8s-2635

Manufacturer Part Number
h8s-2635
Description
Renesas 16-bit Single-chip Microcomputer H8s Family/h8s/2600 Series
Manufacturer
Renesas Electronics Corporation.
Datasheet
4.5
Trap instruction exception handling starts when a TRAPA instruction is executed. Trap instruction
exception handling can be executed at all times in the program execution state.
The TRAPA instruction fetches a start address from a vector table entry corresponding to a vector
number from 0 to 3, as specified in the instruction code.
Table 4-4 shows the status of CCR and EXR after execution of trap instruction exception
handling.
Table 4-4
Legend:
1: Set to 1
0: Cleared to 0
—: Retains value prior to execution.
Interrupt Control Mode
Trap Instruction
Status of CCR and EXR after Trap Instruction Exception Handling
0
2
1
1
I
CCR
Rev. 6.00 Feb 22, 2005 page 101 of 1484
UI
Section 4 Exception Handling
I2 to I0
REJ09B0103-0600
EXR
T
0