h8s-2635 Renesas Electronics Corporation., h8s-2635 Datasheet - Page 715

no-image

h8s-2635

Manufacturer Part Number
h8s-2635
Description
Renesas 16-bit Single-chip Microcomputer H8s Family/h8s/2600 Series
Manufacturer
Renesas Electronics Corporation.
Datasheet
16.3.4
Message reception is performed using mailboxes 0 and 1 to 15. The reception procedure is
described below, and a reception flowchart is shown in figure 16-9.
Initialization (after hardware reset only)
a. Clearing of IRR0 bit in interrupt register (IRR)
b. Bit rate settings
c. Mailbox transmit/receive settings
d. Mailbox (RAM) initialization
Interrupt and receive message settings
a. CPU interrupt source setting
b. Arbitration field setting
c. Local acceptance filter mask (LAFM) settings
Message reception and interrupts
a. Message reception CRC check
b. Data frame reception
c. Remote frame reception
d. Unread message reception
Initialization (After Hardware Reset Only): These settings should be made while the HCAN is
in bit configuration mode.
IRR0 clearing
The reset interrupt flag (IRR0) is always set after a reset or recovery from software standby
mode. As an HCAN interrupt is initiated immediately when interrupts are enabled, IRR0
should be cleared.
Bit rate settings
Set values relating to the CAN bus communication speed and resynchronization. Refer to Bit
Rate and Bit Timing Settings in 16.3.2, Initialization after Hardware Reset, for details.
Receive Mode
Section 16 Controller Area Network (HCAN)
Rev. 6.00 Feb 22, 2005 page 655 of 1484
REJ09B0103-0600

Related parts for h8s-2635