HD6417705F133BV Renesas Electronics America, HD6417705F133BV Datasheet - Page 407

MPU 3V 0K PB-FREE 208 FP

HD6417705F133BV

Manufacturer Part Number
HD6417705F133BV
Description
MPU 3V 0K PB-FREE 208 FP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417705F133BV

Core Processor
SH-3
Core Size
32-Bit
Speed
133MHz
Connectivity
EBI/EMI, FIFO, IrDA, SCI, USB
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
105
Program Memory Type
ROMless
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.4 V ~ 1.6 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
208-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Program Memory Size
-
15.3.10 Minute Alarm Register (RMINAR)
The minute alarm register (RMINAR) is an 8-bit readable/writable register, and an alarm register
corresponding to the minute counter RMINCNT. When the ENB bit is set to 1, a comparison with
the RMINCNT value is performed. For alarm registers RSECAR, RMINAR, RHRAR, RWKAR,
RDAYAR, and RMONAR, a comparison with the corresponding counter value is performed for
those whose ENB bit is set to 1, and for RCR3, a comparison is performed when the YAEN bit is
set to 1. If all of those match, an RTC alarm interrupt is generated.
The range of minute alarm that can be set is 00 to 59 (decimal). Errant operation will result if any
other value is set.
The ENB bit in RMINAR is initialized by a power-on reset, and it is not initialized by manual
reset and standby mode. The remaining RMINAR fields are not initialized by a power-on reset or
manual reset, or in standby mode.
Bit
7
6 to 4
3 to 0
Bit
7
6 to 4
3 to 0
Bit Name
ENB
Bit Name
ENB
Initial Value
0
Initial Value
0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description
Second Alarm Enable
Specifies whether to compare RSECCNT with
RSECAR to generate a second alarm.
0: Not compared
1: Compared
10-unit of second alarm setting in the BCD-code.
The range that can be set is 0 to 5 (decimal).
1-unit of second alarm setting in the BCD-code.
The range that can be set is 0 to 9 (decimal).
Description
Minute Alarm Enable
Specifies whether to compare RMINCNT with
RMINAR to generate a second alarm.
0: Not compared
1: Compared
10-unit of minute alarm setting in the BCD-code.
The range that can be set is 0 to 5 (decimal).
1-unit of minute alarm setting in the BCD-code.
The range that can be set is 0 to 9 (decimal).
Rev. 2.00, 09/03, page 359 of 690

Related parts for HD6417705F133BV