HD6417709SF133B Renesas Electronics America, HD6417709SF133B Datasheet - Page 191

IC SUPERH MPU ROMLESS 208LQFP

HD6417709SF133B

Manufacturer Part Number
HD6417709SF133B
Description
IC SUPERH MPU ROMLESS 208LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417709SF133B

Core Processor
SH-3
Core Size
32-Bit
Speed
133MHz
Connectivity
EBI/EMI, FIFO, IrDA, SCI, SmartCard
Peripherals
DMA, POR, WDT
Number Of I /o
96
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 2.05 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
208-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417709SF133B
Manufacturer:
RENESAS
Quantity:
79
Part Number:
HD6417709SF133B
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417709SF133B
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417709SF133B-V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417709SF133BV
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD6417709SF133BV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
6.4.2
When handling multiple interrupts, an interrupt handler should include the following procedures:
1. Branch to a specific interrupt handler corresponding to a code set in INTEVT and INTEVT2.
2. Clear the cause of the interrupt in each specific handler.
3. Save SSR and SPC to memory.
4. Clear the BL bit in SR, and set the accepted interrupt level in the interrupt mask bits in SR.
5. Handle the interrupt.
6. Execute the RTE instruction.
When these procedures are followed in order, an interrupt of higher priority than the one being
handled can be accepted after clearing BL in step 4. Figure 6.3 shows a sample interrupt operation
flowchart.
6.5
The time from generation of an interrupt request until interrupt exception handling is performed
and fetching of the first instruction of the exception handler is started (the interrupt response time)
is shown in table 6.8. Figure 6.4 shows an example of pipeline operation when an IRL interrupt is
accepted. When SR.BL is 1, interrupt exception handling is masked, and is kept waiting until
completion of an instruction that clears BL to 0.
The code in INTEVT and INTEVT2 can be used as a branch-offset for branching to the
specific handler.
Multiple Interrupts
Interrupt Response Time
Rev. 5.00, 09/03, page 145 of 760