Specifications of EP2AGX190EF29I5N

Number Of Logic Elements/cells
181165
Number Of Labs/clbs
7612
Total Ram Bits
9939
Number Of I /o
372
Voltage - Supply
0.87 V ~ 0.93 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
780-FBGA
Family Name
Arria® II GX
Number Of Logic Blocks/elements
190300
# I/os (max)
372
Frequency (max)
500MHz
Operating Supply Voltage (typ)
900mV
Logic Cells
190300
Ram Bits
10380902.4
Operating Supply Voltage (min)
0.87V
Operating Supply Voltage (max)
0.93V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
780
Package Type
FC-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2AGX190EF29I5N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2AGX190EF29I5N
Manufacturer:
ALTERA
0
Part Number:
EP2AGX190EF29I5N
Manufacturer:
AlTERA
Quantity:
10
Part Number:
EP2AGX190EF29I5N
0
8–14
Figure 8–10. Data Realignment Timing
Arria II Device Handbook Volume 1: Device Interfaces and Integration
rx_channel_data_align
Data Realignment Block (Bit Slip)
Skew in the transmitted data along with skew added by the link causes
channel-to-channel skew on the received serial data streams. If you enabled the DPA
block, the received data is captured with different clock phases on each channel and
might cause the received data to be misaligned from channel to channel. To
compensate for the channel-to-channel skew and establish the correct received word
boundary at each channel, each receiver channel has a dedicated data realignment
circuit that realigns the data by inserting bit latencies into the serial stream.
An optional signal (rx_channel_data_align) controls the bit insertion of each receiver
independently controlled from the internal logic. The data slips one bit on the rising
edge of rx_channel_data_align. The following are requirements for the
rx_channel_data_align signal:
Figure 8–10
factor set to 4.
The data realignment circuit can have up to 11 bit-times of insertion before a rollover
occurs. The programmable bit rollover point can be from 1 to 11 bit-times,
independent of the deserialization factor. The programmable bit rollover point must
be set to equal to or greater than the deserialization factor, allowing enough depth in
the word alignment circuit to slip through a full word. You can set the value of the bit
rollover point using the ALTLVDS megafunction. An optional status signal
(rx_cda_max) is available to the FPGA fabric from each channel to indicate when the
preset rollover point is reached.
An edge-triggered signal
The minimum pulse width is one period of the parallel clock in the logic array
The minimum low time between pulses is one period of the parallel clock
Holding rx_channel_data_align does not result in extra slips
Valid data is available two parallel clock cycles after the rising edge of the
rx_channel_data_align signal
rx_outclock
rx_inclock
rx_out
rx_in
shows receiver output after one bit-slip pulse with the deserialization
3
2
3210
1
Chapter 8: High-Speed Differential I/O Interfaces and DPA in Arria II Devices
0
3
2
321x
1
0
3
2
xx21
1
December 2010 Altera Corporation
0
0321
Differential Receiver