PEF 20525 F V1.3 Infineon Technologies, PEF 20525 F V1.3 Datasheet - Page 194

no-image

PEF 20525 F V1.3

Manufacturer Part Number
PEF 20525 F V1.3
Description
IC CTRL PPP/HDLC SERIAL TQFP-100
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEF 20525 F V1.3

Function
Serial Optimized Communications Controller
Interface
ASYNC, BISYNC, HDLC, PPP
Number Of Circuits
2
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
50mA
Power (watts)
150mW
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
100-LFQFP
Includes
Bit Processor Functions, Serial Communication Controllers (SCCs)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
PEF20525FV1.3X
PEF20525FV13XP
SP000007592
Data Sheet
RDO
RFO
PCE
RSC
RPF
Receive Data Overflow Interrupt
This bit is set to ’1’, if receive data of the current frame got lost because
of a SCC receive FIFO full condition. However the rest of the frame is
received and discarded as long as the receive FIFO remains full and is
stored as soon as FIFO space is available again. The receive status byte
(RSTA) of such a frame contains an ’RDO’ indication. In DMA operation
the ’RDO’ indication is also set in the receive byte count register RBCH.
Receive FIFO Overflow Interrupt
This bit is set to ’1’, if the SCC receive FIFO is full and a complete frame
must be discarded. This interrupt can be used for statistical purposes,
indicating that the host was not able to service the SCC receive FIFO
quickly enough, e.g. due to high bus latency.
Protocol Error Interrupt
This bit is valid in HDLC Automode only.
It is set to ’1’, if the receiver has detected a protocol error, i.e. one of the
following events occured:
• an S- or I-frame was received with wrong N(R) counter value;
• an S-frame containing an Information field was received.
Receive Status Change Interrupt
This bit is valid in HDLC Automode only.
It is set to ’1’, if a status change of the remote station receiver has been
detected by receiving a S-frame with receiver ready (RR) or receiver not
ready (RNR) indication. Because only a status change is indicated via
this interrupt, the current status can be evaluated by reading bit ’RRNR’
in status register STARH.
Receive Pool Full Interrupt
This bit is set to ’1’ if the RFIFO threshold level, set with bit field
’RFTH(1:0)’ in register CCR3H, is reached. Default threshold level is 32
data bytes.
5-194
Register Description (ISR2)
PEB 20525
PEF 20525
2000-09-14