UPD78F0550MA-FAA-AX Renesas Electronics America, UPD78F0550MA-FAA-AX Datasheet - Page 434

no-image

UPD78F0550MA-FAA-AX

Manufacturer Part Number
UPD78F0550MA-FAA-AX
Description
MCU 8BIT 16-SSOP
Manufacturer
Renesas Electronics America
Series
78K0/Kx2-Lr
Datasheet

Specifications of UPD78F0550MA-FAA-AX

Package / Case
*
Voltage - Supply (vcc/vdd)
1.8 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Speed
10MHz
Number Of I /o
12
Core Processor
78K/0
Program Memory Type
FLASH
Ram Size
384 x 8
Program Memory Size
4KB (4K x 8)
Data Converters
A/D 4x10b
Oscillator Type
Internal
Peripherals
LVD, POR, PWM, WDT
Connectivity
I²C, LIN, UART/USART
Core Size
8-Bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD78F0550MA-FAA-AX
Manufacturer:
Renesas
Quantity:
800
Part Number:
UPD78F0550MA-FAA-AX
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
434
(d) Continuous transmission
The next transmit data can be written to transmit buffer register 6 (TXB6) as soon as transmit shift register 6
(TXS6) has started its shift operation. Consequently, even while the INTST6 interrupt is being serviced after
transmission of one data frame, data can be continuously transmitted and an efficient communication rate
can be realized. In addition, the TXB6 register can be efficiently written twice (2 bytes) without having to wait
for the transmission time of one data frame, by reading bit 0 (TXSF6) of asynchronous serial interface
transmission status register 6 (ASIF6) when the transmission completion interrupt has occurred.
To transmit data continuously, be sure to reference the ASIF6 register to check the transmission status and
whether the TXB6 register can be written, and then write the data.
Cautions 1. The TXBF6 and TXSF6 flags of the ASIF6 register change from “10” to “11”, and to “01”
Caution To transmit data continuously, write the first transmit data (first byte) to the TXB6 register.
The communication status can be checked using the TXSF6 flag.
Cautions 1. To initialize the transmission unit upon completion of continuous transmission, be sure
2. When the device is use in LIN communication operation, the continuous transmission
Be sure to check that the TXBF6 flag is “0”. If so, write the next transmit data (second byte)
to the TXB6 register. If data is written to the TXB6 register while the TXBF6 flag is “1”, the
transmit data cannot be guaranteed.
2. During continuous transmission, the next transmission may complete before execution
TXBF6
TXSF6
0
1
0
1
during continuous transmission.
combination of the TXBF6 and TXSF6 flags for judgment. Read only the TXBF6 flag
when executing continuous transmission.
function cannot be used. Make sure that asynchronous serial interface transmission
status register 6 (ASIF6) is 00H before writing transmit data to transmit buffer register 6
(TXB6).
to check that the TXSF6 flag is “0” after generation of the transmission completion
interrupt, and then execute initialization. If initialization is executed while the TXSF6
flag is “1”, the transmit data cannot be guaranteed.
of INTST6 interrupt servicing after transmission of one data frame.
countermeasure, detection can be performed by developing a program that can count
the number of transmit data and by referencing the TXSF6 flag.
Writing enabled
Writing disabled
Transmission is completed.
Transmission is in progress.
CHAPTER 14 SERIAL INTERFACE UART6
Preliminary User’s Manual U19111EJ2V1UD
Writing to TXB6 Register
Transmission Status
To check the status, therefore, do not use a
As a